Use

3
Use
Open all water and gas blocking devices. 
Purge the pipes.
CAUTION: The area in front of the burner
can reach very high temperatures, and there
is a risk of burning on contact.
3.1

Digital display - description

Fig. 3
Digital display
[1] Temperature/error code
[2] Malfunction indicator
[3] Temperature measurement units
[4] Heater in operation (burner turned on)
3.2

Batteries

Battery insertion
▶ Insert the two 1.5 V R20 batteries.
Fig. 4
Inserting the batteries
Replacing the batteries
The batteries must be changed if the red LED starts flashing.
10
Fig. 5
Replacing the batteries
Precautions when using the batteries
Do not dispose of batteries as domestic waste. Take them
to appropriate collecting places for recycling.
Do not insert flat batteries.
Only use the type of batteries indicated.
3.3

Before starting up the heater

CAUTION:
▶ The initial startup of the heater must be
realized by a qualified technician, who
will provide the client with all the
information necessary for its correct
usage.
▶ Check if the gas indicated on the type plate is the same as
the one used at the location.
▶ Open the gas valve.
▶ Open the water valve.
3.4

Turning the heater on and off

Turning on
▶ Press the switch
, position
Fig. 6
Green light on = Main burner on
Therm 4200 – 6 720 821 605 (2017/08)
.