1. Supposing that the device is correctly connected to the a GWN7000 Network and has an IP, it is advised
to set a static IP for the device in question.
To set a static IP for the device on which traffic need to be prioritized, access to GWN7000 WebGUI
Clients and click on edit icon next to the device to set a static IP as shown in below figure.
2. Once set, go to RouterQoSGlobal and make sure that the related WAN port on which the device
belongs to is enabled and has a "Downstream" and "Upstream" bandwidth values.
3. Check "Enable QoS" (a Reboot of GWN7000 will be required after finishing all QoS setup) and click on
"Save".
4. Navigate to Router QoS Upstream QoS.
5. On "Traffic Class", click "Add" to create a traffic Class in order to set the priority, choose the WAN
Interface set on previous step, and define the Upstream bandwidth value.
Figure 4: Fixing a Static IP
Figure 5: Static IP
Figure 6: Enable QoS