2. Installer Troubleshooting Guide

refer to section: 'Important safety Information' first and refer also to 'user Trouble
shooting Guide'.
The following troubleshooting solutions may require the removal of the cover of the
shower. The cover should only be removed by a competent tradesperson and when
doing so they should be aware of the following:
Isolate the electrical and water supply before initially removing the
cover.
Make sure ribbon cable is disconnected when removing the front
cover and reconnect when maintenance is complete.
Mains connections are exposed when the cover is removed.
refer to wiring diagram before making any electrical connections.
Make sure all electrical connections are tight to prevent arcing/
overheating.
Make sure all plumbing connections are watertight.
When following these instructions, it is sometimes necessary to examine the
appliance with the electrical and water supplies turned on. It is therefore essential
that the appropriate safe working practices are followed in accordance with the
current health and Safety Legislation.
If conducting a continuity check using a multimeter, make sure the electrical supply
is IsoLaTeD.
Fault Code Indicator Display
a
0
Possible Cause/Rectification
problem with incoming water supply. Isolator
valves closed, filter blocked or incoming water
supply blocked.
1.
check all isolator valves are fully open.
OR
2.
clean / replace filter, refer to section:
'Maintenance'.
3.
check plumbing system for blockages.
Unidentified Error.
1.
reset / recommission.
2.
replace control pcb.
30