10-2. Outdoor Unit
No.
Part name
Common
1
procedure
Capacitor for
2
compressor
Capacitor for
3
fan motor
Procedures
1) Stop the operation of air-conditioner, and
disconnect the power cord from the AC
supply.
2) Remove packed valve cover and Electric
parts cover.
(2-Screws ∅4 x 10L)
3) Remove the cord clamp (2-Screws ∅4 x 16L)
and disconnect the connecting cable.
4) Remove the upper cabinet (5-Screws ∅4 x 10L)
Pulling out upword.
5) Remove the front cabinet.
(3-Screws ∅4 x 10L)
Pull the front right portion toward you, and
remove it pulling out upward.
1) Perform the common procedure 1.
2) Remove the fixing screw and the capacitor
band.
(1-Screw ∅4 x 10L)
3) Disconnect the lead wires.
1) Perform the common procedure 1.
2) Remove the fixing screw and the capacitor
band.
(1-Screw ∅4 x 10L)
3) Disconnect the lead wires.
63
FILE NO. SVM-10031
Remarks
2-Screws Ø4 x 16L
Cord clamp
2-Screws Ø4 x10L
Packed valve cover
Upper
cabinet
Front
cabinet
Screws
∅ 4 x 10L
Capacitor band
Capacitor for fan motor
Capacitor
for
compressor
Scr ews
Ø4 x10L