Carrier 42NQ012N Service Manual page 40

Wall
Table of Contents

Advertisement

Stripping length of connecting cable
Terminal block
Terminal screw
1(L)
2(N)
screw
Connecting cable
100 mm
Earth line
10 mm
10 mm
Fig. 8-5-10
Model
Power source
50 Hz, 220 – 240 V~ Single phase
Maximum
running current
Plug socket &
fuse rating
Power cord
CAUTION
·
Wrong wiring connection may cause some
electrical parts bum out.
• Be sure to comply with local cords on
running the wire from indoor unit to outdoor
unit (size of wire and wiring method, etc.)
• Every wire must be connected firmly.
NOTE
• Wire type: H07 RN-F or 245 IEC66 (2.0 mm 2 or
more)
3
4
Earth line
Cord clamp
Connecting cable
50 mm
42NQV012N
12A
16A
2
1.5 mm
or more
8-5-5. Remote Controller A or B Selection
Setting
When two indoor units ae installed in seperated rooms,
there is no need to change the selector switch.
<Remote control selector switch>
• When two indoor units are installed in the same room or
adjacent two rooms, if operating a unit, two units may
receive the remote control signal simultaneously and
operate. In this case, the operation can be preserved
by setting either one remote control to B setting.
(Both are set to A setting in factory shipment.)
• The remote control signal is not received when the
settings of indoor unit and remote control are different.
• There is no relation between A setting/B setting and A
room/B room when connecting the piping and cables.
<Remote control A-B selection>
To separate using of remote control for each indoor unit
in case of 2 air conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air
conditioner NO.
2. Point the remote control at the indoor unit.
3. Push and hold [CHK] button on the Remote Control by
the tip of the pencil. "00" will be shown on the display.
4. Press [MODE] during pushing [CHK]. "B" will show on
the display and "00" will disappear and the air conditioner
will turn OFF. The Remote Control B is memorizec.
NOTE : 1. Repeat above step to reset Remote
Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
factory is A.
"B" Display
"00" Display
39
FILE NO. SVM-10031
Revised
Fig. 8-5-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

38ny012n

Table of Contents