Pipe Length And The Elevation - COMFORT-AIRE A-DVC24SF-1 Service Manual

Century dvc series inverter single zone ductless mini-split
Table of Contents

Advertisement

5.3 Pipe length and the elevation

The pipe length and refrigerant amount:
Model
DVC09SF-0
DVC12SF-0
DVC18SF-1
DVC24SF-1
Caution:
The capacity test is based on the standard length and the maximum permissive length is based on the system
reliability.
Service Manual - DVC 09/12/18/24 SF Series
Standard
Pipe size
Length
Gas
Liquid
(m)
7.5
3/8''
1/4''
25 ft
(Ф9.52)
(Ф6.35)
1/2''
1/4''
7.5
25 ft
(Ф12.7)
(Ф6.35)
1/2''
1/4''
7.5
25 ft
(Ф12.7)
(Ф6.35)
5/8"
3/8''
7.5
(Ф15.9)
(Ф9.52)
25 ft
17
16
Max.
Max.
Additional
Elevation
Length
Refrigerant
B (m)
A (m)
(g/m)
10
25
15
32 ft
82 ft
.16 oz/ft
10
25
15
32 ft
82 ft
.16 oz/ft
10
25
15
64 ft
98 ft
.16 oz/ft
20
30
30
.323 oz/ft
64 ft
98 ft

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents