RSG13/14 SPLIT SYSTEM AIR CONDITIONER
INSTALLATION / STARTUP INSTRUCTIONS
/HOMEOWNERS INFORMATION MANUAL
These instructions must be read and understood completely before attempting installation.
Safety Precautions ...............................................2
Unit Location & Installation ....................................2
Indoor Coil Piston Selection ..................................3
Refrigeration Line Sets ..........................................3
Installation of Line Sets .........................................4
Leak Check............................................................4
Evacuating & Charging ..........................................4
These units are designed for use in residential and
commercial type buildings. Units should be installed
with combinations listed in the Air-Conditioning, Heating
and Refrigeration Institute (AHRI) Directory of Certified
Products. Refer to http://www.ahridirectory.org .
Before installation, inspect the unit for shipping damage.
If damage is found, notify the transportation company
immediately and file a concealed damage claim.
CAUTION
Improper Installation, adjustment, alteration, service or
maintenance will void the warranty. The qualified installer
or agency must use factory-authorized kits or accesories
when modifying this product. Refer to the individual
instructions packaged with the kits or accesories when
installing.
These instructions are intended as a general guide
and do not supersede national, state or local codes in
any way.
These instructions must be left with the property
owner.
507708-01

TABLE OF CONTENTS

NOTE
Electrical Connections ..........................................5
Control Wiring ........................................................5
Start-Up Procedure................................................5
Adjusting charge ....................................................5
Single Phase Wiring Diagram.............................7/8
Homeowner's Information .....................................9
Installation or repairs made by unqualified persons can
result in hazards to you and others. Installation MUST
conform with local building codes and with the National
Electric Code NFPA 70/ANSI C1-1993 or current edition
and Canadian Electrical Code Part 1 CSA .
*P507708-01*
Issue 1337
Manufactured By
Comfort-Aire / Century
1900 Wellworth Ave.
Jackson, MI 49203
(P) 507708-01
Page 1 of 9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RSG14 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for COMFORT-AIRE RSG14

  • Page 1: Table Of Contents

    Refer to the individual instructions packaged with the kits or accesories when installing. Manufactured By Comfort-Aire / Century 1900 Wellworth Ave. NOTE Jackson, MI 49203 These instructions are intended as a general guide...
  • Page 2: Safety Precautions

    UNIT LOCATION & INSTALLATION NOTE TO INSTALLING DEALER These instructions and warranty are to be given to the NOTE: In some cases noise in the living area has been owner or prominently displayed near the indoor air traced to gas pulsations from improper installation handler unit.
  • Page 3: Rooftop Installation & Recommendations

    Elevate Unit DO NOT LOCATE THE UNIT: • On brick, concrete blocks or unstable surfaces • Near clothes dryer exhaust vents • Near sleeping area or near windows CAUTION • Under eaves where water, snow or ice can fall directly on the unit Accumulation of water and ice in base pan may cause •...
  • Page 4: Installation Of Line Sets

    Installation Of Line Sets DO NOT fasten liquid or suction lines in direct contact Evacuating And Charging Instructions with the floor or ceiling joist. Use an insulated or suspen- sion type of hanger. Keep both lines separate, and always WARNING insulate the suction line.
  • Page 5: Electrical Connections

    Electrical Connections Ensure the room thermostat is properly installed per instructions shipped with room thermostat. Generally the thermostat should not be exposed to sunlight, drafts or WARNING vibration and should not be mounted on exterior walls. ELECTRICAL SHOCK HAZARD! WARNING Turn OFF electric power before connecting unit, performing any maintenance or removing panels or doors.
  • Page 6 Cooling Cycle Charge Adjustment Procedure NOTE: If a TXV is installed on indoor unit, a hard start kit will be required on all models with Units with Indoor Pistons reciprocating compressors. Refer to the Units installed with indoor pistons require charging specification sheet for details.
  • Page 7: Single Phase Wiring Diagram

    A/C SINGLE PHASE WIRING DIAGRAM (Single-speed condenser fan) 534773W 507708-01 Issue 1337 Page 7 of 9...
  • Page 8 A/C SINGLE PHASE WIRING DIAGRAM (Multi-speed condenser fan) 537511-01 Page 8 of 9 Issue 1337 507708-01...
  • Page 9: Homeowner's Information

    Homeowner’s Information Important System Information Periodically, debris should be brushed from the • Your system should never be operated without a condenser coils. clean air filter properly installed. • Return air and supply air registers should be free WARNING from restrictions or obstructions to allow full flow of air.

This manual is also suitable for:

Rsg13Rsg1442s1mRsg1330s1m-cyRsg1318s1m-cyRsg1336s1m-cy

Table of Contents