Open Circuit Or Short Circuit Of Temperature Sensor Diagnosis And Solution (E5) - COMFORT-AIRE A-DVC24SF-1 Service Manual

Century dvc series inverter single zone ductless mini-split
Table of Contents

Advertisement

Service Manual - DVC 09/12/18/24 SF Series

8.2.5 Open circuit or short circuit of temperature sensor diagnosis and solution (E5)

Error Code
Malfunction conditions
Possible causes
Troubleshooting:
Check the connections
between temperature
sensor and main PCB.
Are the connections
good?
Yes
Check the resistance value
of the sensor, is it normal?
No
Replace the sensor
E4/E5/F1/F2/F3
If the sampling voltage is lower than 0.06V or higher than 4.94V,
the LED will display the failure.
Wiring error
Sensor faulty
PCB faulty
No
Correct the connections.
Replace indoor or
Yes
outdoor main PCB.
37