Performing a Cold Boot

A cold boot restarts the MC18 and erases all user stored records and entries that are not saved in flash
memory (Application and Platform folders). Never perform a cold boot unless a warm boot does not solve the
problem.
NOTE Any data previously synchronized with a computer can be restored during the next ActiveSync operation.
Performing Cold Boot when the MC18 is Docked Inside the Cradle
Use this procedure to perform a cold boot when the MC18 is docked inside the cradle:
Press and hold the scan key for 10 seconds until the display powers off.
1.
Release the scan key when the MC18 re-boots.
2.
Performing Cold Boot when MC18 is Out of the Cradle
Use this procedure to perform a cold boot when the MC18 is out of the cradle:
Insert the terminal reboot tool into the MC18 power connector and then press and hold the scan key for 10
1.
seconds until the display powers off - the MC18 reboots.
Release the scan key and remove the terminal reboot tool from the MC18.
2.
Scan Key
Terminal Reboot Tool
Figure 1-17
Power Connector
Terminal Reboot Tool
Special Considerations 1 - 17