Specifications - Mitsubishi Electric PEFY-P-VML-E Data Book

City milti
Hide thumbs Also See for PEFY-P-VML-E:
Table of Contents

Advertisement

1. Specifications

Power source
Cooling capacity
Heating capacity
Cooling
Power consumption
(50/60Hz)
Heating
Cooling
Current
Heating
External finish
Height
Dimension
Width
Depth
Net weight
Heat exchanger
Type
Airflow rate
External
Fan
static
pressure
(Low/Mid/High)
Type
Motor
Output
Air filter (option)
(Flare)
Refrigerant
pipe dimension
Liquid
(Flare)
Drain pipe dimension
❇ 2
Noise level
Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling : Indoor 33˚CDB/28˚CWB,Outdoor 33˚CDB
Heating : Indoor 0˚CDB/-2.9˚CWB,Outdoor 0˚CDB/-2.9˚CWB
❇ 2 It is measured in anechoic room.
a). The cooling and heating capacities are the maximum capacities that were obtained by operating in the above air conditions
and with a refrigerant pipe of about 7.5m.
b). The actual capacity characteristics vary with the combination of indoor and outdoor units. See the technical information.
c). The operating noise is the data that was obtained by measuring it 1.5m from the bottom of the unit in an anechoic room.
(Noise meter A-scale value)
d). The figure of Electrical characteristic indicates at 220V and at middle external static pressure.
e). When the 100% fresh air indoor units are connected, the maximum connectable indoor units to 1 outdoor unit are as follows.
110%(100% in case of heating below-5˚C)
f ). Operational temp range is cooling : from 21˚CDB/15.5˚C WB to 43˚CDB/35˚CWB.
✻Thermo off (Fan) operation automatically starts either when temperature is lower than 21˚CDB in cooling mode or when
the temperature exceeds 20˚CDB in heating mode.
g ). As the room temp is sensed by the thermo in the remote controller or the one in the room, be sure to use ether remote
controller or room thermo.
h ). Dry mode is Not available. Fan mode operation during the thermo off in Cooling/Heating mode.
i ). The fan would temporarily stops either with R2/WR2 system or in defrost.
j ). In any case, the air flow rate should be kept lower than 110% of the above chart.Please see " Fan curves " for the details.
k ). When this unit is used as sole A/C system, be careful about the dew in air outlet grilles in cooling mode.
l ). Un-conditioned outdoor air such as humid air or cold air blows to the indoor during thermo off operation.
Please be careful when positioning indoor unit air outlet grilles, ie take the necessary precautions for cold air, and also
insulate rooms for dew condensation prevention as required.
m). Air filter must be installed in the air intake side.The filter should be attached where easy maintenance is possible in case of
usage of field supply filters.
n ). Long life filter cannot be used with Hi-efficiency filter together.
PEFY-P80VMH-E-F
❇ 1
kW
❇ 1
kW
kW
kW
A
A
mm
mm
mm
kg
Sirocco fan ✕ 1
3
m
/min
208V
Pa
220V
Pa
230V
Pa
240V
Pa
kW
Gas
mm
mm
208, 220V
dB(A)
230, 240V
dB(A)
Heat pump models
Heating : from -10˚CDB to 20˚CDB
PEFY-P140VMH-E-F
~ 220-240V 50Hz / ~ 208-230V 60Hz
9.0
8.5
0.16/0.21
0.16/0.21
0.67/0.91
0.67/0.91
Galvanizing
380
1000
900
50
Cross fin (Aluminum plate fin and copper tube)
9.0
35/85/170
40/115/190
50/130/210
80/170/220
Single phase induction motor
0.09
Synthetic fiber unwoven cloth filter(long life)
ø 15.88
ø 19.05 (R22,R407C)
ø 9.52
32 (1-1/4 inch)
27/38/43
33/43/45
Cooling only
110%
1- 46
16.0
15.1
0.29/0.33
0.29/0.33
1.24/1.48
1.24/1.48
1200
70
Sirocco fan ✕ 2
18.0
35/85/170
50/115/190
60/130/220
100/170/240
0.14
ø 15.88 (R410A)
28/38/43
34/43/45

Advertisement

Table of Contents
loading

Table of Contents