Mitsubishi Electric PEFY-P-VMH-E Installation Manual
Mitsubishi Electric PEFY-P-VMH-E Installation Manual

Mitsubishi Electric PEFY-P-VMH-E Installation Manual

Air-conditioners for building application
Hide thumbs Also See for PEFY-P-VMH-E:

Advertisement

Quick Links

Air-Conditioners For Building Application
INDOOR UNIT
PEFY-P-VMH-E

INSTALLATION MANUAL

For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
INSTALLATIONSHANDBUCH
Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Veuillez lire le manuel d'installation en entier avant d'installer ce climatiseur pour éviter tout accident et vous assurer d'une utilisation correcte.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore d'aria.
INSTALLATIEHANDLEIDING
Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert.
MANUAL DE INSTALAÇÃO
Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado.
E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™
°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ÂÁηٿÛÙ·Û˘ ÚÈÓ ·Ú¯›ÛÂÙ ÙËÓ
ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÌÔ‡.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным руководством по
установке до выполнения установки кондиционера.
MONTAJ ELK‹TABI
Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› monte etmeden önce bu elkitab›n› dikkatle okuyunuz.

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PEFY-P-VMH-E

  • Page 1: Installation Manual

    Air-Conditioners For Building Application INDOOR UNIT PEFY-P-VMH-E INSTALLATION MANUAL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen. MANUEL D’INSTALLATION Veuillez lire le manuel d’installation en entier avant d’installer ce climatiseur pour éviter tout accident et vous assurer d’une utilisation correcte.
  • Page 2 [Fig. 3.1.1] Type 40~140 A Fan and motor removal door B Duct dimension Type 200 · 250 Type PEFY-P40·50·63VMH-E PEFY-P71·80VMH-E 1004 PEFY-P100·125·140VMH-E 1130 1204 1000 1050 PEFY-P200·250VMH-E 1250 1326 1100 1100 [Fig. 3.1.2] Type 40~140 Type 200 · 250 B Duct dimension C Electrical components case 150~200 D Air inlet...
  • Page 3 [Fig. 6.2.1] Type 40 - 140 Type 200 · 250 A Air inlet B Refrigerant piping (liquid) C Refrigerant piping (gas) D Control box E Drain outlet F Air outlet [Fig. 6.3.1] Type 40 - 140 A Thermal insulation tubing 1 K Thermal insulation B Caution: L Pull...
  • Page 4 [Fig. 7.2.1] A Downward slope 1/100 or more B Drain hose (Accessory) C Indoor unit D Collective piping E Maximize this length to approx. 10 cm [Fig. 8.0.1] [Fig. 9.1.1] A Switch 16 A B Overcurrent protection 16 A C Indoor unit D Total operating current be less than 16 A E Pull box A Air inlet...
  • Page 5: Table Of Contents

    Always use an air cleaner, humidifier, electric heater, and other accesso- copper as specified in the JIS H3300 “Copper and copper alloy seamless ries specified by Mitsubishi Electric. pipes and tubes”. In addition, be sure that the inner and outer surfaces of - Ask an authorized technician to install the accessories.
  • Page 6: Before Getting Installed

    • Do not use a refrigerant other than R410A or R407C. • Install the power cable so that tension is not applied to the cable. - If another refrigerant (R22, etc.) is used, the chlorine in the refrigerant may - Tension may cause the cable to break and generate heat and cause a fire. cause the refrigerator oil to deteriorate.
  • Page 7: Selecting An Installation Site

    3. Selecting an installation site • Select a location so that air can be blown into all corners of the room. Note: Always install access doors in the specified positions for service mainte- • Avoid locations exposed to outside air. nance.
  • Page 8: Refrigerant Pipe And Drain Pipe Specifications

    6. Refrigerant pipe and drain pipe specifications To avoid dew drops, provide sufficient antisweating and insulating work to the re- 1 Select the thickness of insulating material by pipe size. frigerant and drain pipes. Pipe size Insulating material’s thickness When using commercially available refrigerant pipes, be sure to wind commer- 6.4 mm to 25.4 mm More than 10 mm cially available insulating material (with a heat-resisting temperature of more than...
  • Page 9: Connecting Refrigerant Pipes And Drain Pipes

    Refrigerant amount adjustment Refer to the installation manual for the outdoor unit for details on adjusting the amount of refrigerant. 7. Connecting refrigerant pipes and drain pipes 7.1. Refrigerant piping work • Store the piping to be used during installation indoors and keep both ends of the piping sealed until just before brazing.
  • Page 10: Power Supply Wiring

    <Table 1> System configuration For a single-refrigerant system For a multi-refrigerant system Transmission cable length Less than 120 m More than 120 m Regardless of length Building, clinic, hospital or communications station without noise supposedly generated Facility example Residence or independent store from inverter equipment, private power gen- All facilities (for noise judgment)
  • Page 11: Selecting The Static Pressure

    Caution: Wire the power supply so that no tension is imparted. Otherwise disconnec- tion, heating or fire result. 9.4. Selecting the static pressure Type 40 - 140 The external static pressure can be changed over as required. For the selection of the static pressure, insert an attachment between the connector of the motor lead wire and the control box.
  • Page 12 This product is designed and intended for use in the residential, commer- cial and light-industrial environment. • Low Voltage Directive 73/23/EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following EU regulations: 336/EEC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

Table of Contents