Mitsubishi Electric PMFY-P VBM-E Installation Manual
Mitsubishi Electric PMFY-P VBM-E Installation Manual

Mitsubishi Electric PMFY-P VBM-E Installation Manual

Air-conditioners for building application - indoor unit
Hide thumbs Also See for PMFY-P VBM-E:

Advertisement

Air-Conditioners For Building Application

INDOOR UNIT

PMFY - P VBM-E

INSTALLATION MANUAL

For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie-
nungsanleitung und das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil exté-
rieur pour une utilisation sûre et correct.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het buitenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, prima di installare il condizionatore d'aria leggere attentamente il presente manuale
ed il manuale d'installazione dell'unità esterna.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade exte-
rior antes de instalar o aparelho de ar condicionado.
For use with the R410A
Bei Verwendung von R410A
A utiliser avec le R410A
Bij gebruik van R410A
Para utilizar con el R410A
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
PARA O INSTALADOR
Uso del refrigerante R410A
Para utilizaçao com o R410A
R410A ile beraber kullanmak için
English (GB)
Deutsch (D)
Français (F)
Nederlands (NL)
Español (E)
Italiano (I)
Português (P)
Türkçe (TR)

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PMFY-P VBM-E

  • Page 1: Indoor Unit

    Air-Conditioners For Building Application INDOOR UNIT PMFY - P VBM-E For use with the R410A Uso del refrigerante R410A Bei Verwendung von R410A A utiliser avec le R410A Para utilizaçao com o R410A Bij gebruik van R410A R410A ile beraber kullanmak için Para utilizar con el R410A INSTALLATION MANUAL FOR INSTALLER...
  • Page 2 Contents ....................6 1. Safety precautions ..................2 2. Installing the indoor unit................2 5. Installing the grille ..................7 6. Test run ......................9 3. Refrigerant pipe and drain pipe ..............4 Note: : Indicates an action that must be avoided. tions”.
  • Page 3: Installation Location

    2. Installation location (mm) 2.2. Service space (Fig. 2-2) following diagram; so centre the main unit against the opening of ceiling, ensur- ing that the respective opposite sides on all sides of the clearance between them becomes identical. Air outlet Ceiling panel Min.
  • Page 4: Refrigerant Pipe And Drain Pipe

    2. Installing the indoor unit 1. 2. 3. (mm) 1. Thread washers 1 2 2, washer without insulation 1, 2 nuts. * Position insulated washer 2 with the insulated surface pointing down, as in the et between washers 1 and 2, which are already in place, and secure it. Do the same in all four places.
  • Page 5 3. Refrigerant pipe and drain pipe 3.2. Connecting pipes (Fig. 3-2) 45°±2° with commercially available insulation materials (heat-resistant to 100 °C or more, sulate carefully. Warning: ing the compressor. A Flare cutting dimensions Fig. 3-2 Copper pipe O.D. Flare dimensions ø6.35 8.7 - 9.1 ø9.52...
  • Page 6: Electrical Work

    3. Refrigerant pipe and drain pipe (mm) 7 , then secure the material with a band. (Both insulating material and band are supplied with [Fig.3-5] A Unit B Insulating material 7 Fig. 3-5 E Insertion margin F Matching [Fig.3-6] A Drain port sectional view Fig.
  • Page 7: Installing The Grille

    4. Electrical work 1. Wiring transmission cables M1 M2 M1 M2 M1 M2 Types of transmission cable Shielding wire CVVS or CPEVS TB15 TB5 TB15 Cable diameter More than 1.25 mm² Length Less than 200 m 2. M-NET Remote control cables Types of remote control cable Shielding wire MVVS Cable diameter 0.5 to 1.25 mm²...
  • Page 8 5. Installing the grille A Points for securing the grille E Drainage pan B Points for securing the grille F Places for securing front grille C Indoor unit D Ceiling surface each Fig. 5-2 with the ceiling surface. and that wiring connections and arrangements are complete. Fig.
  • Page 9 5. Installing the grille tween the front panel and the ceiling surface. If there are gaps, the wind may come in and condensation may result. A Ceiling surface B Indoor unit C Grille Fig. 5-6 nals. Warning: B Test run display 1 Turn on the power at least 12 hours before the test run.
  • Page 10 ................78 ................74 ............... 74 ............80 ................81 ............76 2.1. × × 30 Fig. 2-1...
  • Page 11 Fig. 2-2 1000 74,5 74,5 Fig. 2-3 Fig. 2-4 Fig. 2-5 Fig. 2-6...
  • Page 12 Fig. 2-7 Fig. 2-8 Fig. 2-9 2.5. ° 288,5 Fig. 2-10 3.1. ø12,7 (96) ø6,35 (56) Fig. 3-1...
  • Page 13 45°±2° Fig. 3-2 14 - 18 Fig. 3-3 – Fig. 3-4...
  • Page 14 . 3-5] Fig. 3-5 3-6] Fig. 3-6 Fig. 3-7 Fig. 3-8 4.2. Fig. 4-1 M1M2 S TB15 Fig. 4-2...
  • Page 15 M1 M2 M1 M2 M1 M2 TB15 TB5 TB15 M1 M2 M1 M2 M1 M2 4.4. Fig. 4-3...
  • Page 16 4 × 16 Fig. 5-1 Fig. 5-2 Fig. 5-3 Fig. 5-4 Fig. 5-5...
  • Page 17 5.4. Fig. 5-6 TEST RUN COOL, HEAT °C °C SIMPLE TEMP. ON/OFF MENU ON/OFF FILTER BACK MONITOR/SET CHECK TEST PAR-21MAA CLOCK OPERATION CLEAR...
  • Page 18 This product is designed and intended for use in the residential, commercial and light-industrial environment. Importer: Mitsubishi Electric Europe B.V. French Branch German Branch Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany Belgian Branch Autobaan 2, 8210 Loppem, Belgium Irish Branch Italian Branch...

Table of Contents