Mitsubishi Electric PEFY-P-VML-E Operation Manual

Air-conditioners for building application
Hide thumbs Also See for PEFY-P-VML-E:

Advertisement

Air-Conditioners For Building Application
INDOOR UNIT
PEFY-P-VML-E
PEFY-P-VMM-E
PEFY-P-VMH-E
PLFY-P-VLMD-E

OPERATION MANUAL

For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du climatiseur.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y
correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro della stessa.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de airconditioner gebruikt.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado.
E°XEIPI¢IO O¢H°IøN XPH™Eø™
°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ¯Ú‹Ûˆ˜ ÚÈÓ ı¤ÛÂÙ Û ÏÂÈÙÔ˘ÚÁ›· ÙË
ÌÔÓ¿‰· ÎÏÈÌ·ÙÈÛÌÔ‡.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Для обеспечения правильного и безопасного использования следует ознакомиться с инструкциями, указанными в данном
руководстве по эксплуатации, тщательным образом до того, как приступать к использованию кондиционера.
IfiLETME ELK‹TABI
Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› iflletmeden önce bu elkitab›n› dikkatle okuyunuz.
PDFY-P-VM-E
PFFY-P-VLEM-E
PFFY-P-VLRM-E

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PEFY-P-VML-E

  • Page 1: Operation Manual

    Air-Conditioners For Building Application INDOOR UNIT PEFY-P-VML-E PDFY-P-VM-E PEFY-P-VMM-E PFFY-P-VLEM-E PEFY-P-VMH-E PFFY-P-VLRM-E PLFY-P-VLMD-E OPERATION MANUAL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
  • Page 2 Bottone dell’unità del comando a distanza Remote controller-Button Controlador remoto-Botón Fernbedienungs-Taste Knop afstandbediening Touche Commande à distance Botão do controlo remoto 1 Pulsante [Regolazione della temperatura ambiente] 2 Pulsante [Timer/continuo] 3 Pulsante [Selezione modalità di funzionamento] 4 Pulsante [Selezione ora] Pulsante [Impostazione dell’ora] CENTRALLY CONTROLLED 1Hr.
  • Page 3 ∆ËϯÂÈÚÈÛÙ‹ÚÈÔ-∫Ô˘Ì› Кнопка контроллера ДУ Uzaktan kumanda ünitesi - Dü¤me 1 ∫Ô˘Ì› [ƒ‡ıÌÈÛ˘ ıÂÚÌÔÎÚ·Û›·˜ ‰ˆÌ·Ù›Ô˘] 2 ∫Ô˘Ì› [ÃÚÔÓfiÌÂÙÚÔ/Û˘Ó¯‹˜] 3 ∫Ô˘Ì› [∂ÎÏÔÁ‹˜ ÏÂÈÙÔ˘ÚÁ›·˜] 4 ∫Ô˘Ì› [∂ÎÏÔÁ‹˜ ¯ÚfiÓÔ˘] ∫Ô˘Ì› [ƒ‡ıÌÈÛ˘ ÒÚ·˜] 5 ∫Ô˘Ì› [ÁÚ›ÏÏÈ·˜] 6 ∫Ô˘Ì› [ƒ‡ıÌÈÛ˘ Ù·¯‡ÙËÙ·˜ ·ÓÂÌÈÛÙ‹Ú·] 7 ∫Ô˘Ì› [¶¿Óˆ/οو ηÙ‡ı˘ÓÛ˘ ÚÔ‹˜ ·¤Ú·] 8 ∫Ô˘Ì›...
  • Page 4 Display dell’unità del comando a distanza Remote controller-Display Controlador remoto-Indicador Fernbedienung-Anzeige Display afstandbediening Affichage Commande à distance Visualização do controlo remoto A Ora corrente/Timer B Comando centralizzato C Timer attivato D Si verifica un’anomalia E Modo funzionamento: COOL, DRY, AUTO, FAN, HEAT F Preparazione della modalità...
  • Page 5 ∆ËϯÂÈÚÈÛÙ‹ÚÈÔ-∂›‰ÂÈÍË Дисплей контроллера ДУ Uzaktan kumanda ünitesi-Göstergesi A ∆Ú¤¯Ô˘Û· ÒÚ·/ÃÚÔÓԉȷÎfiÙ˘ B ∫ÂÓÙÚÈÎÔ‡ ÂϤÁ¯Ô˘ C ÃÚÔÓԉȷÎfiÙ˘ √¡ D ¶·ÚÔ˘ÛÈ¿˙ÂÙ·È ·ÓˆÌ·Ï›· E º¿ÛË ÏÂÈÙÔ˘ÚÁ›·˜: æÀ•∏, ∞ºÀ°ƒ∞¡™∏, ∞À∆√ª∞∆∏ §∂π∆√Àƒ°π∞, ∞¡∂ªπ™∆∏ƒ∞™, £∂ƒª∞¡™∏ F ¶ÚÔÂÙÔÈÌ·Û›· ÁÈ· ÙË ÏÂÈÙÔ˘ÚÁ›· ı¤ÚÌ·ÓÛ˘ G §ÂÈÙÔ˘ÚÁ›· ·fi„˘Í˘ H ƒ‡ıÌÈÛ˘ ıÂÚÌÔÎÚ·Û›·˜ I §ÂÈÙÔ˘ÚÁ›·...
  • Page 6 1: In case of rear inlet 2: In case of bottom inlet Bei Einlass von hinten Bei Einlass von unten <PEFY-P-VML-E> En cas d’entrée arrière En cas d’entrée sur le dessous En el caso de unidad interior trasera En el caso de unidad interior inferior...
  • Page 7: Table Of Contents

    Check frequently that the ground wire from the outdoor unit is properly • Use only accessories authorized by Mitsubishi Electric and ask your connected to both the unit’s ground terminal and the grounding electrode. dealer or an authorized company to install them. If accessories are in- 1.2.
  • Page 8: Disposing Of The Unit

    Warning: your dealer. Leaving the unit as it is under such conditions can result in • Do not remove the front panel or the fan guard from the outdoor unit fire or failure. when it is running. You could be injured if you touch rotating, hot or high- •...
  • Page 9: Room Temperature Adjustment

    Caution: [PLFY-P125VLMD, PDFY-P20~80VM series] Never expose your body directly to cool air for a long time. Excessive expo- Fan speed : 4 stages sure to cool air is bad for your health, and should therefore be avoided. Display: (Low)→ (Mid2)→ (Mid1)→...
  • Page 10: Timer Setting

    Display example of timer setting CENTRALLY CONTROLLED 1Hr. ON OFF ˚C CLOCK CHECK FILTER CHECK MODE ˚C TEST RUN STAND BY ERROR CODE FUNCTION NOT AVAILABLE DEFROST The example shows a timer set for operation start at 8:00 and end at 17:00. TEMP.
  • Page 11: Caring For The Machine

    Prevent intrusion of heat during air-cooling Carry out ventilation sometimes • To prevent the intrusion of heat during cooling operation, provide a curtain or a • Since the air periodically gets dirty in a room that is kept closed for a long time, blind on the window to block out direct sunlight.
  • Page 12: Installation, Transferring Works, And Checking

    7. Installation, transferring works, and checking Regarding place for installation • Never connect the grounding wire to a gas pipe, water pipe, arrester, or Consult with your dealer for details on installation and transferring the installation. telephone grounding wire. For details, consult with your dealer. •...
  • Page 13 PEFY-P-VML-E series Model P20VML-E P25VML-E P32VML-E Item Power source ~220-240V 50/60Hz Cooling capacity*1 / Heating capacity*1 2.2/2.5 2.8/3.2 3.6/4.0 Dimension Height / Width / Depth 225/720/550 225/720/550 225/720/550 Net weight Airflow rate (Low-Middle-High) /min 4.8/5.8/7.9 4.8/5.8/7.9 4.8/5.8/9.5 External static pressure...
  • Page 14 PFFY-P-VLEM-E/PFFY-P-VLRM-E series Model P25VLEM-E P40VLEM-E P63VLEM-E Item P20VLEM-E P32VLEM-E P50VLEM-E Power source ~220-240V 50Hz / ~208V-230V 60Hz Cooling capacity*1 / Heating capacity*1 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 Dimension Height / Width / Depth 630/1,050/220 630/1,050/220 630/1,170/220 630/1,170/220 630/1,410/220 630/1,410/220 Net weight Airflow rate (Low-High) /min...
  • Page 15 This product is designed and intended for use in the residential, commer- cial and light-industrial environment. • Low Voltage Directive 73/23/EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following EU regulations: 336/EEC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

Table of Contents