Running-In Period - MWM MS 3.9L Operation And Maintenance Manual

Table of Contents

Advertisement

Running-in Period

During the running-in period, follow these recommendations:
It is not advisable to operate the engine at light loads for a long time.
Maximum load: It can be applied to a new engine as soon as it is in operation, since the engine's temperature is in the
ideal operation range.
Do not operate the engine at high speed without load.
Do not overload the engine.
Do not operate the engine with sudden accelerations, during the engine's lifetime.
Before starting the engine, check its lubricating oil, engine coolant and fuel levels.
Do not keep the engine idling for warming it. Instead, vary the engine speed.
Do not keep the engine idling without need.
Keep the operating temperature between 82 and 98 °C.
Note:
The operator is responsible for the correct usage of this product during running-in period. To ignore the
recommendations above mentioned will cause a decrease of the product life duration, with consequent
increase of lubricating oil consumption to higher levels than those ones defined by project.
NP 085.70.69 - 01/06