HDVD Sync Termination: You need to set 75 ohms in the case of composite sync
(Sync type = Hsync or Vsync).
VCO Clock Hold: When you cannot get correct radar image in the case of composite
sync or sync on green, you may get correct image with setting that this parameter is
"off".
Gain and Offset and black bottom level: These adjust contrast and brightness by
setting RGB values.