(2) Remove the front panel and the control box cover. (Refer to Fig. 7)
< How to remove the front panel and control box cover >
(1) Open the front panel to the point where it stops.
(2) Push the hook on either side of the front panel towards the center of the main unit and remove. (You can
also remove it by sliding the front panel either to the left or right and pulling it forward.)
(3) Remove the screw from the control box cover and pull the handle forward.
(3) Point the pipe in the direction it will be passed out.
For right, bottom-right, and back-right piping (Refer to Fig. 8)
• Wrap the drain hose and the refrigerant piping together with the
insulating tape (3) so that the drain hose is below the refrigerant
piping.
For left, bottom-left, and left-back piping
• Remove the front grille. (Refer to Fig. 9)
< How to remove the front grille >
(1) Remove the screws grille clamps and tabs securing the front grille.
(2) Remove the front grille.
Tab position
(3 places)
Front grille securing positions
for 71 class
8
Hook
Hook
Flat screwdriver,
etc.
Screw position
How to remove
(3 places)
grille clamps
(for 100 class only)
Remove the clamps
under the front grille
with a flat screwdriver.
Front panel
(1)
(2)
Fig. 7
Tab
Fig. 9
Control box cover
Hook
(2)
Handle
Screw
Insulating tape (3)
(accessory)
Refrigerant piping
Fig. 8
Tab position
(4 places)
Screw position (6 places)
Grille clamp
positions (3 places)
Front grille securing positions
for 100 class
(3)
Drain hose