Amprobe’s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. This warranty is your only remedy . All other warranties - whether express, implied or statutory - including implied warranties of fitness for a particular purpose or merchantability, are hereby excluded.
Page 5
NEEDLE LOCK e ZERO RS-3 PRO RS-1007 PRO ➊ Current jaws ➋ Jaw opening lever ➌ Function / Range selector wheel ➍ Needle Lock ➎ Volt – Amp needle - zero adjust, Ohms - ∞ adjust ➏ (On side) Ohms zero adjust ➐...
RS-3 PRO / RS-1007 PRO CAT IV Analog Clampmeter Series CONTENTS Symbols ........................5 Safety Information ....................5 Warnings and Precautions .................5 Unpacking and Contents ..................6 Introduction ......................6 Operation ......................6 Measuring AC Voltage (See Fig. 1) ..............6 AC Current Measurement (See Fig. 2) ............6 Measuring Resistance /Continuity (See Fig.
SymbOLS Battery Refer to the manual Double insulated Dangerous Voltage Alternating Current Earth Ground Conforms to relevant Complies with EU Australian standards. directives Do not dispose of this Underwriters product as unsorted Laboratories.[Note: municipal waste.
UNPACkINg ANd CONTENTS Your shipping carton should include: RS-1007 Pro or RS-3 Pro Test lead set 1.5V AAA battery (installed) F 0.5 A 1000V Fuse (installed) Users Manual Carrying Case If any of the items are damaged or missing, immediately return the complete package to the place of purchase for an exchange.
or by other qualified instrument service personnel. The front panel and case can be cleaned with a mild solution of detergent and water. Apply sparingly with a soft cloth and allow to dry completely before using. Do not use aromatic hydrocarbons or chlorinated solvents for cleaning. battery Replacement (see fig.
Page 10
OL Protection: 600 V ac rms AC Amp (50/60 Hz) Ranges: RS-1007 Pro: 15 / 40 / 100 / 300 / 1000 Arms RS-3 Pro: 6 / 15 / 40 / 100 /600 Arms Accuracy: ± 3 % of Full Scale Ohms Range: 1000 ohms 25 Ohms mid-scale...