Installation Guide 3200 Series Gateway Standalone & 3200 Series Gateway 1+1 November 27, 2014...
Page 2
TMG7800-DS3+1, TMG7800-STM1+1, Tdev, TMP800, TMP6400, TMP6400-CTRL, TMP6400-TMS, Tmonitor, TM1000, TM3000, Toopack, Toolpack API, TB640, TB-8, TB-16, and TB-Video, are trademarks of TelcoBridges Inc. All other trademarks are the property of their owners. This information is subject to change without notice.
TMG3200 (TMG3200-RJ, TMG3200-TE, TMG3200-DS3, or TMG3200-STM1), or TSG3200 (TSG3200-RJ, TSG3200-TE, TSG3200-DS3), or TMGIP3200. 3200-RJ This term is used when a description applies to the TMG3200-RJ and TSG3200-RJ. 3200-TE This term is used when a description applies to the TMG3200-TE and TSG3200-TE. 3200-DS3 This term is used when a description applies to the TMG3200-DS3 and TSG3200- DS3.
Page 4
3200 series +1 and 1+1 Patch Panel(s). If you are installing a 1+1 System read and follow the instructions provided in those sections and pages. Contact Us If you have comments about this guide or any other TelcoBridges technical documentation, please send an email to marketing@telcobridges.com.
Table of Contents Table of Contents Section 1 Introduction........................1 Recognizing a 3200 Series Standalone versus a 3200 Series 1+1 System .......2 1.1.1 3200 Series Standalone .....................2 1.1.2 3200 Series 1+1 System ....................2 1.1.3 Product Images ........................3 Installation Prerequisites .....................5 Preventing Electrostatic Discharge Damage...............6 Recommended Reading......................6 Section 2...
Page 6
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.5.7 Start Up ..........................44 Adding a 3200 Series +1 Unit to an Existing Standalone, Creating a 3200 Series 1+1 System46 2.6.1 Reconfigure a Standalone Unit as a Primary Unit in an 3200 Series 1+1 System....46 2.6.2 Install the 3200 Series +1 Unit on the Equipment Rack ............49 2.6.3...
3200 Series 1+1 System: 3200 series unit operating in conjunction with a 3200 series +1 unit, and 1+1 patch panel(s). Note 1+1 Patch panels are only available for the TMG3200 and TSG3200. The following topics are covered: • Section 1.1 “Recognizing a 3200 Series Standalone versus a 3200 Series 1+1 System”...
3200 Series Standalone and 3200 Series 1+1 System Installation Guide Recognizing a 3200 Series Standalone versus a 3200 Series 1+1 System 1.1.1 3200 Series Standalone The 3200 series standalone consists of one telecom unit. The front and rear views are shown in figure 1.1 on page 3.
Introduction 1.1.3 Product Images TMG3200/TSG3200/TMGIP3200 (front view) TMG3200-RJ/TMG3200-RJ+1 and TSG3200-RJ/TSG3200-RJ+1 TMG3200-TE/TMG3200-TE+1 and TSG3200-TE/TSG3200-TE+1 TMG3200-DS3/TMG3200-DS3+1 and TSG3200-DS3/TSG3200-DS3+1 TMG3200-STM1/TMG3200-STM1+1 and TSG3200-STM1/TSG3200-STM1+1 TMGIP3200 Figure 1.1 3200 Series and 3200 Series +1 Front and Rear Views...
Introduction Installation Prerequisites For the installation to proceed without interruption, it is important that you verify that you have all necessary materials on hand. 3200 Series Standalone 3200 Series 1+1 System Adequate space for the installation of the Adequate space for the installation of your 3200 Series Standalone.
This document assumes that you have a clear understanding of the installation of the equipment described in this document and have been trained to work with the equipment.If you have any technical questions, TelcoBridges TB Support (technical support team) can be reached at the following numbers or an email can be sent to: support@telcobridges.com.
Section 2 Installing the Equipment This chapter provides information about the following topics: • Section 2.1 “Package Contents” • Section 2.2 “Rack Mounting the 3200 Series Standalone or 3200 Series 1+1 System” • Section 2.3 “Choosing your Connection Procedures” • Section 2.4 “3200 Series Standalone System”...
In the box, you will find the following items: • One 3200 series unit: TMG3200 (TMG3200-RJ, TMG3200-TE, TMG3200-DS3, or TMG3200-STM1), or TSG3200 (TSG3200-RJ, TSG3200-TE, TSG3200-DS3), or TMGIP3200. See figure 1.1 on page 3. • One set of mounting brackets and screws, used to mount the 3200 series unit to a 19" rack.
One Quick Installation Guide (two-sided document that provides a pictorial view of the equipment setup). • Two AC or DC power cables Specifically with the TMG3200-TE and TSG3200-TE, you will also have: • One or two (2) patch panel(s) •...
Page 16
One Quick Installation Guide (two-sided document that provides a pictorial view of the equipment setup). • Two AC or DC power cables Specifically with the TMG3200-TE+1 and TSG3200-TE+1, you will also have: • One or two patch panel(s) • Two SCSI cables per patch panel.
Page 17
Installing the Equipment 1+1 Patch Panels 1+1 patch panels are required for the proper connection of the 3200 series 1+1 system, and are automatically included when a 3200 +1 series unit is ordered. Table 2.1 lists the various 1+1 patch panels that you will receive based upon the type of 3200 series telecom unit integrated in your 3200 series 1+1 system.
3200 Series Standalone and 3200 Series 1+1 System Installation Guide Rack Mounting the 3200 Series Standalone or 3200 Series 1+1 System The 3200 series equipment is mounted on a customer provided equipment rack using the mounting hardware packaged in the box. 2.2.1 Prerequisites To rack mount the equipment, you will need:...
Mount the 3200 series unit as mentioned above: Install the 3200 series +1 unit below the TMG3200, as shown in figure 2.1 on page 14. To attach the 3200 series +1 unit to the equipment rack, follow the previous procedure.
Page 20
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 3200 Series Standalone 3200 Series Unit 3200 Series 1+1 System 3200 Series Unit 3200 Series +1 Gateway Network Gateway 1+1 1 or 2 1+1 Patch Panels Gateway Network Gateway 1+1 Figure 2.1 Rack mounting the Equipment...
Installing the Equipment Choosing your Connection Procedures Use the following diagram to guide you to the appropriate section, based on your chosen installation. Choosing Your Setup 3200 Series 3200 Series 1+1 Adding a Unit Standalone System I am setting I am setting up a I am adding up a 3200 Series...
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 3200 Series Standalone System If you are here, you have a 3200 series unit that you will setup as a standalone system. This section covers the following procedures for a 3200 series standalone system: •...
Installing the Equipment 2.4.1 Connecting to the 3200 Series Gateway Management Interface The 3200 series gateway management interface enables administrators to perform management tasks on the 3200 series unit. Prerequisites To communicate with the management interface, the following is needed: •...
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.4.2 Connecting to a VoIP Network The 3200 series gateway features dual GigE ports for connection to different VoIP networks. This provides an access point to manage VoIP traffic. Should one of the IP networks fail, the 3200 series gateway will continue to manage VoIP traffic using the alternate network.
Connecting to the PSTN The 3200 series gateway features a variety of interfaces to the PSTN network. Note This section only applies to the TMG3200 and TSG3200 systems. Prerequisites To connect to the PSTN network, you must comply with one of the following: •...
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.4.3.1 RJ48C Type Interface (T1/E1) for the 3200-RJ A 3200-RJ with 16 RJ48C type ports enables the connection to T1/E1 lines. The termination impedance is set at 100 ohms for T1 lines and 120 ohms for E1 lines. It is possible to connect an external balun in order to convert the line impedance to 75 ohms.
Installing the Equipment 2.4.3.2 SCSI Interface (T1/E1) for the 3200-TE A 3200-TE with 4 SCSI connectors enables the connection to T1/E1 lines. The termination impedance is set at 120 ohms. It is possible to connect an external balun in order to convert to 75 ohms. Note All ports may not be active.
Page 28
3200 Series Standalone and 3200 Series 1+1 System Installation Guide SCSI patch panel 1 (rear view) 16-31 0-15 SCSI patch panel 2 (rear view) 16-31 0-15 SCSI patch panel (front view) Figure 2.5 3200-TE with SCSI connectors...
Installing the Equipment 2.4.3.3 Dual BNC Interface (DS3) for the 3200-DS3 A 3200-DS3 with 3 sets of BNC connectors enables the connection to DS3 lines. See figure 2.6 on page 23. Note All ports may not be active. DS3 ports are activated by software license; the number of active ports depends on the licenses purchased.
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.4.3.4 Optical Interface (OC3/STM-1) for the 3200-STM1 A 3200-STM-1, with one main and one backup OC3 or STM1 port enables connection to OC3/STM1 lines. See figure 2.7 on page 24. Refer to table 2.3 on page 24 for a listing of optical interfaces. The default SFP module for OC3/STM1 connection is SMF, intermediate reach, (SFP-OC3-IR1) 1310 nm with LC type connectors.
Installing the Equipment 2.4.4 Grounding the Equipment Chassis As a standard safety practice, the chassis of the 3200 series gateway must be properly grounded to protect against any contact with an electrical fault condition. It is recommended that the chassis be connected to an earth ground.
The 3200 series gateway AC model is furnished with two AC power connectors. To connect to AC Power: Connect an AC power cable between the AC connector of the TMG3200 and an AC supply. See figure 2.9 on page 26.
Installing the Equipment 2.4.5.2 Connecting to DC Power The 3200 series gateway DC model is furnished with two DC power connection ports. In addition, each DC powered unit is supplied with two DC power cables. To connect o DC power: Connect one DC cable, supplied with the 3200 series gateway, as shown in figure 2.10 on page 27, to the rear of the unit.
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.4.6 Start Up The first time that you connect to a 3200 series gateway, the web portal will appear and you will be asked to select how you would like to configure the 3200 series gateway. You will want to be sure to set the role as a 3200 series standalone.
Installing the Equipment 3200 Series 1+1 System If you are here, you are installing a 3200 series 1+1 system. This section covers the following procedures: • Section 2.5.1 “Connecting to the 3200 Series 1+1 System Management Interfaces” on page 30. •...
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.5.1 Connecting to the 3200 Series 1+1 System Management Interfaces The management interface enables administrators to perform management tasks on a 3200 series 1+1 system. Prerequisites To communicate with the management interface, the following is needed: •...
Installing the Equipment 2.5.2 Connecting to the Control Network The 3200 series control network enables a 3200 series unit to be connected to a 3200 series +1 unit, allowing for a sharing of system resources. Prerequisites To connect to the control network, you will need: •...
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.5.3 Connecting the 3200 Series 1+1 System VoIP Network(s) Each 3200 series unit and 3200 series +1 unit features dual GigE ports for connection to different VoIP networks. This provides an access point to manage VoIP traffic. Should one of the IP networks fail, the 3200 series 1+1 system will continue to manage VoIP traffic using the alternate network.
2.5.4 Connecting to the PSTN in a 3200 Series 1+1 System Note This section only applies to the TMG3200 and TSG3200 systems. The 3200 Series 1+1 system features a variety of interfaces to the PSTN network. Prerequisites To connect to the PSTN network, you must comply with one of the following: •...
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.5.4.1 RJ48C Type Interface (T1/E1) for the 3200-RJ and 3200-RJ+1 A 3200 Series 1+1 system with an RJ TDM interface featuring 16 RJ48C type ports enables the connection to T1/E1 lines. The termination impedance is set at 100 ohms for T1 lines and 120 ohms for E1 lines.
Page 41
Installing the Equipment 3200-RJ 3200-RJ+1 3200 series unit Gateway Network Gateway 1+1 3200 series +1 unit From Network Figure 2.14 3200-RJ and 3200-RJ+1 connecting to the TDM 1+1 8/T1/E1 1+1 patch panel...
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.5.4.2 SCSI Interface (T1/E1) for the 3200-TE and 3200-TE+1 A 3200-TE and 3200-TE+1 each with 4 SCSI connectors enables the connection to T1/E1 lines. The termination impedance is set at 120 ohms. It is possible to connect an external balun in order to convert to 75 ohms.
Page 43
Installing the Equipment 3200-TE 3200-TE+1 rear view Gateway Gateway front view From Network Figure 2.15 3200-TE and 3200-TE+1 connecting to the TDM 1+1 32/T1/E1 1+1 patch panel...
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.5.4.3 Dual BNC Interface (DS3) for the 3200-DS3 and 3200-DS3+1 A 3200-DS3 and 3200-DS3+1 each with 3 sets of BNC connectors enables the connection to DS3 lines. figure 2.16 on page 38. Note All ports may not be active.
Installing the Equipment 2.5.4.4 Optical Interface (OC3/STM-1) A 3200-STM1 and 3200-STM+1, each with one main and one backup OC3 or STM1 port enables the connection to OC3/STM1 lines. See figure 2.17 on page 40. Refer to table 2.4 on page 39 for a listing of optical interfaces.
Page 46
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 3200-STM1 3200-STM1+1 Gateway Gateway Main Main Main From Network 3200 Series 3200 Series Unit 1+1 Unit Figure 2.17 3200-STM1 and 3200-STM1 +1 connecting to the STM1 1+1 patch panel...
Installing the Equipment 2.5.5 Grounding the Equipment Chassis As a standard safety practice, the chassis of the 3200 series gateway must be properly grounded to protect against any contact with an electrical fault condition. It is recommended that the chassis be connected to an earth ground.
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.5.6 Powering Up The 3200 series unit and 3200 series +1 unit are furnished with two (2) AC or two (2) DC power connections. Only once all other equipment installation work has been completed should the 3200 series 1+1 system be powered up.
Installing the Equipment 2.5.6.2 Connecting to DC Power The 3200 series and 3200 series +1 DC models are furnished with two DC power connection ports. In addition, each DC powered device is supplied with two DC power cables. To connect the 3200 series and 3200 series +1 unit to DC Power Connect the first DC power connector of the 3200 series and 3200 series +1 units to DC power source one.
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.5.7 Start Up After powering up the 3200 series 1+1 system, you must configure both units, one as primary and the other as secondary. Once these configuration settings are applied, your 3200 series 1+1 system will start up and display the web portal configuration management tool.
Page 51
Installing the Equipment Once you confirm the changes, a progress page is displayed.
3200 Series Standalone and 3200 Series 1+1 System Installation Guide Adding a 3200 Series +1 Unit to an Existing Standalone, Creating a 3200 Series 1+1 System Warning: This procedure will require some system downtime. In order to add a 3200 series +1 unit to a 3200 series standalone unit, you must perform the following procedures: •...
Page 53
Installing the Equipment Select a host from the Host Configuration List. Select the Status tab.
Page 54
3200 Series Standalone and 3200 Series 1+1 System Installation Guide Select Reset Host Role. Follow the instructions of the web portal to configure your unit as a primary unit in a new 3200 series 1+1 system.
Section 2.2 “Rack Mounting the 3200 Series Standalone or 3200 Series 1+1 System” on page 12. 2.6.3 Install a 1+1 Patch Panel Note This section only applies to the TMG3200 and TSG3200. If your system features a 3200-RJ TDM interface, use a 1+1 patch panel (8/T1/E1). Gateway Gateway Refer to Section 2.5.4.1 “RJ48C Type...
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.6.4 Connect to the 3200 Series 1+1 Management Interface The Management interface enables administrators to perform management tasks on a 3200 series 1+1 system. Follow the procedure described in Gigabit Ethernet Switch Section 2.5.1 “Connecting to the 3200 Series 1+1 System Management Interfaces”...
VoIP Network 2 2.6.7 Connect to the PSTN Network Note This section only applies to the TMG3200 and TSG 3200. 3200 series gateways feature a variety of interfaces to the PSTN network. If your system features a 3200-RJ TDM interface, refer to Section 2.5.4.1 “RJ48C Type...
3200 Series Standalone and 3200 Series 1+1 System Installation Guide 2.6.8 Power Up the 3200 Series 1+1 System The 3200 series and 3200 series +1 units are furnished with either two AC or DC power connections. Only once all other equipment installation work has been completed should the 3200 series 1+1 system be powered up.
Installing the Equipment 2.6.9 Start Up Note To learn about the IP address for your system or how to change it, refer to Section 3.5 “Changing the 3200 Series Gateway Management Port IP Address” on page 60. Connect to the web portal of the 3200 series 1+1 system. The Welcome page appears. Follow the web portal instructions to configure your unit as a secondary unit in a new 3200 series 1+1 system.
3200 Series Standalone and 3200 Series 1+1 System Installation Guide Verifying the LED Status Indications When the 3200 series 1+1 system has been powered up, verify the front panel of the unit to determine that all indications are normal. Once the 3200 series 1+1 system has run successfully through its system boot procedures, the following will be displayed in an alternating fashion as described in table 2.5 on page 54: Table 2.5...
Page 61
Installing the Equipment Table 2.6 Reset Menu Options Menu Choices Description M | Options: >Shutdown Graceful shutdown of the 3200 series 1+1 system. This takes a few minutes. Press the reset button to restart the system. Rst telecom Reboots the telecom platform of the 3200 series 1+1 system. Rst host Reboots the linux host of the 3200 series 1+1 system.
3200 Series Standalone and 3200 Series 1+1 System Installation Guide Powering Down Powering down the 3200 series 1+1 system requires that the Linux embedded host be shut down. In order to do this, you must connect to the management interface using SSH, and enter: shutdown -hP now Attention DO NOT TURN OFF the power to the 3200 series gateway using the power switch...
Section 3 Initial System Configuration This chapter provides information about the following topics: • Section 3.1 “Connecting to the Serial Port of the 3200 Series Gateway” • Section 3.2 “Configuring the Terminal Emulator Application” • Section 3.3 “Connecting to the 3200 Series Gateway” •...
3200 Series Standalone and 3200 Series 1+1 System Installation Guide Connecting to the Serial Port of the 3200 Series Gateway Note By default, the management port is set to DHCP. Sections 3.1 and 3.2 provide instructions on how to convert the DHCP management port to a static IP address.
Initial System Configuration Configuring the Terminal Emulator Application Before communicating with the management interface, you must first configure a terminal emulator or console application to communicate with the 3200 series system in order to configure initial settings. Available terminal emulation software includes: •...
The 3200 series gateway enables you to retrieve system information with the following shell commands: • tbproduct (retrieve the 3200 series gateway product type). See http://docs.telcobridges.com/mediawiki/index.php/TMG:Get_Product_Type, for further information. • tbserial (retrieve the 3200 series gateway serial number). See http://docs.telcobridges.com/mediawiki/index.php/TMG:Get_Serial_Number, for further information.
Changing VoIP Interface Addresses The default address of the VoIP interfaces of the 3200 series gateway can be modified. To learn how this is done, refer to the Web Portal tutorial guide on the Telcobridges TB Wiki at docs.telcobridges.com. Note With regard to sections 3.2, 3.3, 3.4 3.5, 3.6 or 3.7, please visit the TBWiki at:...
Page 68
3200 Series Standalone and 3200 Series 1+1 System Installation Guide...
Section 4 System Backups This chapter provides information about the following topics: • Section 4.1 “Creating a Database Backup” • Section 4.2 “Downloading a Database Backup” • Section 4.3 “Uploading a Database Backup” • Section 4.4 “Restoring a Database Backup”...
For more detailed information with regard to any of the points described in this section, please refer to the TBWiki: http://docs.telcobridges.com Creating a Database Backup It is important that backups be made of system configuration settings in the event of a system failure. It is recommended that a backup be made once the system has been configured.
3200 Series Standalone and 3200 Series 1+1 System Installation Guide RJ48C Wiring Diagram: Crossover and Straight Cables RJ 48 (T1/E1/J1) Wiring Schematic: Crossover Cable RX/Ring/- RX/Ring/- RX/Tip/+ RX/Tip/+ Not Connected Not Connected TX/Ring/- TX/Ring/- TX/Tip/+ TX/Tip/+ Not Connected Not Connected Not Connected Not Connected Not Connected...
Need help?
Do you have a question about the TMG3200 and is the answer not in the manual?
Questions and answers