Thank you for choosing Bolt. The Bolt P12 Compact Battery Pack will extend the flash capacity and boost the recycle speed of your flash unit. Its compact design and compatibility with a range of AA battery types make it easy and convenient to use. The easy-loading battery tray fits 12 AA batteries and is designed to ensure fast and effortless battery installation and replacement.
Page 4
Precautions • Please read and follow these instructions, and keep this manual in a safe place. • Do not attempt to disassemble or repair this product. There are components inside that can produce a hazardous electric shock. • Keep this product and AA batteries away from children. •...
Contents Overview ..............................6–7 Installing Batteries ............................8-9 Using the P12 with a Flash ...........................10 High-Voltage Indicator ..........................11 Battery Indicator Lights ........................... 12-13 Using the Soft Case ............................14 Cleaning the Compact Battery Pack ......................15 Troubleshooting ............................16-17 Specifications ...............................18 Warranty ...............................19...
Overview High-voltage indicator Battery indicator lights Power button Battery tray Battery bay Battery tray release buttons Carry case Flash cable Overview...
Page 8
• Dispose of batteries properly. Never heat them or throw them into a fire, as this could cause the batteries to leak corrosive liquids, generate heat, or explode. Installing Batteries and Powering the P12 The P12 Compact Battery Pack requires that all 12 AA batteries are installed in order to operate the unit. Two battery types can be used: •...
Important! • All 12 batteries must be installed. The P12 will not operate with less than 12 batteries. • When removing the batteries, be careful not to touch the contacts. • Replace all batteries at the same time. Do not mix battery types or brands, or insert used and new batteries together.
Using the P12 with a Flash The P12 provides a fast flash recycle time and hundreds of full-power flashes with each set of batteries used. To operate your flash with the battery pack, follow these steps: Install the appropriate batteries into your flash, and turn it on.
High-Voltage Indicator The high-voltage indicator alerts you to the status of the P12. High-voltage indicator Function Steady light High-voltage output is normal. The P12 is connected to the flash. There is no high-voltage output. The P12 automatically switches to standby mode, and it will automatically turn off in approximately 30 minutes.
To get the most from your P12 Compact Battery Pack: • Use the P12 in environments with moderate temperatures. When some battery types are cold, they begin to lose their ability to supply power. However, this doesn’t mean they’ve lost their charge. They will regain the ability to supply power when their temperature returns to a more moderate level.
Page 13
• To conserve battery life, turn the flash unit off or disconnect the P12 from it during long standby periods. Very little power is consumed when the P12 is in standby mode. The amount may vary according to working conditions and the specific flash model used with the pack.
Using the Soft Case Make sure the P12 is correctly oriented in the case. The flash cable should extend out of the top of the case, and the indicator lights should be visible. Close the top flap over the P12, and adjust the touch-connect strap for a secure and snug fit.
Cleaning the Compact Battery Pack If the metal contacts in the battery tray become dirty or corroded, you can clean them with isopropyl (rubbing) alcohol and a cotton swab. An eraser can also be used to rub corrosion off of the contacts. Do not touch the metal contacts with your fingers, because they can transfer oil and residues.
After that, the power won’t turn on. The high-voltage indicator blinks continuously. There has been an error or malfunction. Turn off the P12, and check the flash connections and the batteries in the P12 as well as the flash.
Page 17
The high-voltage indicator blinks four times This indicates that the batteries are low, and that the per second. P12 is taking too long to recycle the flash. Replace the batteries in the P12. Only one of the battery indicators is There is less than 20% battery power remaining.
Specifications Operating voltage 14.4 to 20 V DC Max: 12 A Operating current Shutdown Current: ≤3 μA Operating temperature 32°F to 122°F (0°C to 50°C) Storage temperature -4°F to 140°F (-20°C to 60°C) Storage humidity 35% to 95% Power AA batteries (×12) Dimensions (W ×...
To obtain warranty coverage, contact the BOLT Customer Service Department to obtain a return merchandise authorization (“RMA”) number, and return the defective product to BOLT along with the RMA number and proof of purchase. Shipment of the defective product is at the purchaser’s own risk and expense. For more information or to arrange service, visit www.boltflashes.com or call Customer Service at 212-594-2353.