Wireless Mesh Communication Module; Fast Network Address Reset; Ip Futura Module / Intuitive Internal Ip Network Card - Resource Data Management PR0750-MOB Installation & User Manual

Mercury 2 & intuitive mercury mobile controller
Table of Contents

Advertisement

Mercury 2 & Intuitive Mobile Controller User Guide

Wireless Mesh Communication Module

RDM Wireless Mesh System, please refer to the RDM Wireless Mesh Communication Module user guide, which can be obtained from
the RDM website, for information regarding connecting a controller to a Wireless Mesh network.
The value shown in 485A is of the form 05-6. This means the controller would try to log onto a Genus compatible or RDM Wireless Mesh
network using the name 'RC05-6'.
The gAdd option displays (in hexadecimal format) the underlying network address assigned to the controller when it was logged onto the
network.
The rLog option allows the controller to be logged back onto the network with its current name. The 'rLog' message will flash for
confirmation. Press the Enter button to execute the command, Up or Down buttons to cancel.

Fast Network Address Reset

The CLrA option will clear out the network address and name in the controller. The 'ClrA' message will flash for confirmation. Press the
Enter button to execute the command, Up or Down buttons to cancel.
To enter this mode, hold the Enter, Up and Down buttons together for approximately 3 seconds until the message CLrA appears on the
display. CLrA is the first option in the menu consisting of the following options:
Display Option
CLrA
Clear the address/name from the controller
ESC
Exit Setup mode
Pressing the Enter button to select the CLrA option will cause the 'CLrA' message to flash for confirmation, if the network type is set to
Genus compatible. Press the Enter button to execute the command, Up or Down buttons to cancel. If the network type is not set to
Genus compatible then the ClrA message will not flash and the ESC option can be used to exit the menu.

IP Futura module / Intuitive Internal IP Network card

In an IP system there are two options,
IP-L
IP-r
IP-L allows you to fix an IP address into the controller, which you would use when you are connecting the controllers onto a customer's
local area network. This would allow the customer to view each controller using Internet Explorer
IP-r allows you to give each controller on the system a unique number. This number is then allocated a dynamic IP address by the
system DHCP server (such as the RDM Data Manager)
IP-L
To configure the communication module or network card for IP-L, set all three rotary switches to zero. The module should then be
connected to the controller. In the case of an Intuitive Mercury controller where the network card is already fitted, the controller should be
powered off, all three rotary switches set to zero and the controller powered on.
1.
nEt. From the function menu you can now select nEt
Warning
Ensure that all power is
switched off before
installing or maintaining
this product
Please Note
Press enter and the display will show "IP-L", press enter
You can now set the address using the table below
Display
Option
IP-1
IP Address byte 1
IP-2
IP Address byte 2
IP-3
IP Address byte 3
IP-4
IP Address byte 4
nL
Network Mask Length
gt-1
Gateway Address byte 1
gt-2
Gateway Address byte 2
gt-3
Gateway Address byte 3
gt-4
Gateway Address byte 4
ESC
Exit network menu. N.B. this option must be selected to save
any changes made in this menu
Revision 1.1
www.resourcedm.com
Page 14 of 21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pr0720-mobPr0760-mobPr0710-mob

Table of Contents