All sensor temperatures

Below are the various sensor temperatures that are visible under line 3 in the control panel. Note that
not all the sensors are standard but are available as accessories for different areas of use. To get there
press "Menu" in the control panel and then turn the knob to line 3. Then press "Select".
Line 3
Temperature readings
Return radiator GT1
Off ##,#° Now ##,#°
Return
Temperature readings
Out GT2
###,#°
Return
Temperature readings
Hot water GT3
Off ##,#° Now ##,#°
Return
Temperature readings
Shunt, flow GT4
Tgt ##,#° Now ##,#°
Return
Temperature readings
Room GT5
Tgt ##,#° Now ##,#°
Return
Temperature readings
Compressor GT6
###,#°
Return
Temperature readings
Heat trfluid out GT8
###,#°
Return
Temperature readings
Heat tr fluid in GT9
###,#°
Return
Temperature reading
Ht trfld(coll)inGT10
###,#°
Return
Temperature reading
Httrfld(coll)outGT11
###,#°
Return
Shows the temperature of the heating system return flow.
Standard
This varies depending on the outdoor temperature.
Shows the outdoor temperature.
Standard
Shows the temperature in the outer container of the electric
water heater's bottom part. This temperature is around 5°C
Only in C-
serie
lower than the temperature in the hot water tank.
If an extra mixing valve is used for e.g. floor heating then
the flow pipe is visible on the circuit. It varies with the
Accesso-
ries
outdoor temperature.
If a room sensor is used, you see the temperature of the
room where the sensor is located.
Accesso-
ries
The sensor shows the working temperature of the compres-
Standard
sor. It varies between around 70°C and 125°C.
The sensor shows the outgoing temperature from the heat
pump. It varies depending on the outdoor temperature and if
Standard
the heat pump is in hot water production mode.
The sensor shows the ingoing temperature to the heat pump.
It varies as mentioned above. Please note that for safety
Standard
reasons the heat pump stops when this shows a temperature
of more than 48°C.
The sensor shows the temperature from the bore hole or the
ground. It normally varies between -5°C and 8°C throughout
Standard
the year.
The sensor shows the temperature to the bore hole or the
ground. It is normally 1.5°C till 5°C lower than heat transfer
Standard
in.
21