Enhanced functions
As user you have access to extra functions. Keep the Heat button
pressed down for five seconds and go into Menu to gain access to
these displays. You will automatically return to level 1 again after
30 seconds.

Line 1

Main menu
Indoor temperature
settings
Return
Select
Temperature settings
Setting of room
sensor infl.
Return
Select
Temperature settings
Setting of holiday
function
Return
Select
Temperature settings

Remote control

temperature
Return
Select
Temperature settings
Setting of summer
disconnection
Return
Select
Line 2
Main menu
Adjusting the hot
water settings
Return
Select
Hot water setting
Interval for
hot water peak
Return
Select
1
With extra
sensor
only
1.11
Only
with
extra
sensor
and at
1.12
operating
mode A
only
With extra
sensor ,
remote
control
1.13
and at
operating
mode A
only
At
operating
modes A
1.14
and B
only
2
At
operating
mode A
2.2
only
Keep the button pressed down for 5 seconds.
You have pressed Menu and are on row 1. Press "Select"
and turn the knob and the displays scroll up. You can then
choose to enter the display you require. Each display has a
number.
With a room sensor installed you can set the value of how
much you want it to affect the outdoor sensor. A high value
gives more affect from the room sensor. Please note the
room sensor only fine tunes the heat curve. It is therefore
important that you set the basic settings for the heat curve
and fine tuning from the start.
If a room sensor is installed you can set the number of days
that the room temperature is lowered to 15°C here. The
temperature is not adjustable and it does not affect the hot
water. Normal operation is resumed when the period is
over.
If a room sensor and remote control is installed you can set
the required room temperature here. You can then use the
telephone to increase the temperature to normal.
This equipment is available as an accessory.
At this set temperature the heat pump only produces hot
water.
Using the knob you have moved to the hot water settings in
row 2.
Setting for intervals for the continual raising of the hot
water temperature. If you choose for example7 days, the
temperature is raised using the electric water heater once a
week to around 65°C (Operating mode A with electric
water heater only).