Setting terminal parameters

To configure and manage the switch through the console port, you must run a terminal emulator program,
HyperTerminal or PuTTY, on your configuration terminal. You can use the emulator program to connect a
network device, a Telnet site, or an SSH site. For more information about the terminal emulator programs,
see the user guides for these programs.
The following are the required terminal settings:
Bits per second—9,600.
Data bits—8.
Parity—None.
Stop bits—1.
Flow control—None.

Powering on the switch

Before powering on the switch, verify that the following conditions are met:
The power cord is correctly connected.
The input power voltage meets the requirement of the switch.
The console cable is correctly connected.
The configuration terminal (a PC, for example) has started, and its serial port settings are consistent
with the console port settings on the switch.