Alert type
Icon
Warning
Caution
Acknowledging alerts
The Alerts softkey is labelled Alerts Acknowledge if there is an un-acknowledged alarm or
warning in the system.
You acknowledge the most recent alarm or warning by pressing the Alerts Acknowledge
softkey. The cursor is then automatically moved to the Alerts panel, and you can use the
arrow keys to move up and down in the list of alerts.
Repeat pressing this softkey to continue to acknowledge alerts from the top of the Alerts
panel. The sort order of alerts is the severity (i.e. alarm before warning), then age.
If no active alerts or warnings are present, the softkey is labelled Alerts. Pressing this key
moves the cursor to the Alerts panel.
Press the EXIT key to exit the Alerts panel.
When an Alarm or Warning is acknowledged, the alert icon stops flashing and changes to the
acknowledged icon. The siren continues to sound if there are remaining unacknowledged
alarms or warnings, otherwise it is muted.
The acknowledged alert is not moved to its new position in the sort order until there has
been 2 seconds without any alerts being acknowledged.
All alerts remain in the Alerts panel until the reason for the alarm is rectified.
The Alerts dialog
The Alerts dialog includes a list of active alerts together with a historic listing of the last 100
alerts. All alerts in the Alerts dialog include a time stamp.
The alert system
| R2009/R3016 User manual
State
Indication
•
Flashing symbol
and descriptive
Active - not
text
acknowledged, not
silenced
•
Audible signal
•
Flashing symbol
and descriptive
Active - not
text
acknowledged,
silenced
•
No audible signal
•
Steady symbol and
descriptive text
Active -
acknowledged
•
No audible signal
•
Steady symbol and
descriptive text
Active - responsibility
transferred
•
No audible signal
•
Flashing symbol
and descriptive
Rectified - not
text
acknowledged
•
No audible signal
•
Steady symbol and
descriptive text
Active
•
No audible signal
63