ADJUSTMENT:
LENS AND CCD READ POSITION ADJUSTMENT
1) Loosen the lens fixing screw and CCD board fixing screw.
2) Adjust the position of the lens and CCD board so that the waveform appears as shown in the figure below.
3) Fix the lens fixing screw and CCD board fixing screw.
"Never connect land "AMON"
To LED array for CCD Unit.
Extension cord (Part No. PQZZ2K12Z)
Lens fixing screws
CCD board fixing screws
VID
AG
AMON
FIG
CN7
CN6
Extension Cord
(Part No. PQZZ8K18Z)
To CCD baord
| 103 |
Oscilloscope setting
CH1 ........... 0.5 V/div
CH2 ........... 2 V/div
TIME .......... 1 ms
Trigger ....... CH2
Mode ......... AC
OSCILLOSCOPE
CH1
CH2
To point "FTG".
To point "VID".
(DIGITAL BORAD)
WAVEFORM
KX-F910BX
MAX
(for Lens)
MAX
(for CCD Board)