Bit No.
7
Reserved for future T.3 operation features
8
Reserved for future T.3 operation features
9
Transmitter - T.4 operation
Receiver - T.4 operation
10
Data signalling rate
11, 12
V.27 ter fallback mode
(0, 0)
V.27 ter
(0, 1)
V.29
(1, 0)
V.27 ter and V.29
(1, 1)
13
Reserved for new modulation system
14
Reserved for new modulation system
15
Vertical resolution = 7.7 line/mm
16
Two-dimensional coding capability
17, 18
Recording width capabilities
(0, 0)
1728 picture elements along scan line
length of 215 mm } 1%
(0, 1)
1728 picture elements along scan line
length of 215 mm } 1% and
2048 picture elements along scan line
length of 255 mm } 1% and
2432 picture elements along scan line
length of 303 mm } 1%
(1, 0)
1728 picture elements along scan line
length of 215 mm } 1% and
2048 picture elements along scan line
length of 255 mm } 1%
(1, 1)
Invalid (see Note 7)
19, 20
Maximum recording length capability
(0, 0)
A4 (297 mm)
(0, 1)
Unlimited
(1, 0)
A4 (297 mm) and B4 (364 mm)
(1, 1)
Invalid
Signal.....DCS (Digital Command Signal)
Identification Signal Format.....X1000001
(Example)
Bit No.
21, 22, 23
Minimum scan line time capability at the receiver
20 ms at 3.851/mm: T7.7=T3.85
(0, 0, 0)
(0, 0, 1)
40 ms at 3.851/mm: T7.7=T3.85
(0, 1, 0)
10 ms at 3.851/mm: T7.7=T3.85
(1, 0, 0)
5 ms at 3.851/mm: T7.7=T3.85
(0, 1, 1)
10 ms at 3.851/mm: T7.7=1/2 T3.85
(1, 1, 0)
20 ms at 3.851/mm: T7.7=1/2 T3.85
(1, 0, 1)
40 ms at 3.851/mm: T7.7=1/2 T3.85
(1, 1, 1)
0 ms at 3.851/mm: T7.7=T3.85
DIS/DTC
DIS/DTC
DCS
Receiver - T.4 operation
Data signalling rate
2400 bit/s V.27 ter
4800 bit/s V.27 ter
9600 bit/s V.29
7200 bit/s V.29
Vertical resolution = 7.7 line/mm
Two-dimensional coding
Recording width
1728 picture elements along scan line
length of 215 mm } 1%
2432 picture elements along scan line
length of 303 mm } 1% and
2048 picture elements along scan line
length of 255 mm } 1% and
Invalid
Maximum recording length
A4 (297 mm)
Unlimited
B4 (364 mm)
Invalid
Function:
Notifies of capacity of receiving machine obtained
at DIS and announces the transmission mode of
the sender. The added data signals are as follows.
Standard setting
Minimum scan line time
20 ms
40 ms
10ms
5ms
0ms
| 149 |