Ricoh Aficio Color 6010 Service Manual page 359

Hide thumbs Also See for Aficio Color 6010:
Table of Contents

Advertisement

SC CODE TABLE
SC
Item
Detection Conditions
No.
SC401 Image transfer
- Timing & Condition -
belt motor lock
·
The feedback signal
from the motor is still out
of range 2 seconds after
the trigger signal is sent.
·
The feedback signal
becomes out of range for
2 seconds while the
trigger signal is ON.
SC402 Image transfer
- Timing & Condition -
belt lubricant
The current leak is detected
brush current
more than 2 seconds.
leak
Related
Possible Causes
SC
·
Defective image
transfer belt motor
·
Defective image
transfer belt motor
drive board
·
Mechanical
problem (drive
transmission)
·
Defective high
voltage supply
board (Q1).
·
Defective I/O
control board
·
Defective main
control board
14
Troubleshooting Procedure
1. Check if the connectors on the image transfer belt drive
board (CN740 and 741) and I/O control board (CN220)
are properly connected.
2. Check the harnesses are damaged.
3. Replace the image transfer belt motor control board.
4. Replace image transfer belt motor.
5. Check if anything causes the load of the belt motor to
be increased.
[ Signal Check ]
·
Motor OK: CN220-A2 or TP153 on the I/O control
board
1. Check if the connectors on the terminal and high
voltage supply board (Q1) are properly connected and
if the harnesses are damaged.
2. Clean the receptacles.
3. Replace the high voltage supply board (Q1).
4. Replace the I/O control board.
5. Replace the main control board.
[ Signal Check ]
·
Leak detection: CN215-B7 or TP137 on I/O control
board
30 March, 1999
Type
D
D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aficio color 6110