Download Print this page

Specification - Sealey TM105 Instructions

Professional auto-ranging digital clamp meter ncvd 6-function

Advertisement

1) AC DC
AC (alternating current)
and DC (direct current).
2)
Minus sign.
3) 1.8.8.8
2000 count (0 to 1999) measurement
reading.
4) AUTO
AutoRange mode.
5) REL
Relative mode.
6)
Diode test mode.
7) •)))
Audible Continuity.
8) HOLD
Data Hold mode.
9) °C, °F, µ, m, V, A, K, M, Ω, Units of measure list.
10) MAX
MAX hold mode.

3. SPECIFICATION

Function
AC Current
(50/60Hz)
DC Voltage
AC Voltage
Resistance
Clamp size ................................. Opening 1.2" (30mm) approx.
Diode Test .................................. Test current of 0.3mA typical; Open circuit voltage 1.5V DC typical.
Continuity Check ....................... Threshold <150Ω; Test current < 0.5mA.
Low Battery Indication ............... "
Overrange Indication ................. "OL" is displayed.
Measurements Rate .................. 2 per second, nominal.
Input Impedance ........................ 10MΩ (VDC and VAC).
Display ....................................... 2000 counts LCD.
AC Current................................. 50-60Hz (AAC).
AC Voltage bandwidth .............. 50-60Hz (VAC).
Operating Temperature .............. 41 to 104oF (5 to 40°C).
Storage Temperature ................. -4 to 140oF (-20 to 60°C).
Operating Humidity .................... Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°C).
Storage Humidity ....................... <80%.
Operating Altitude ...................... 7000ft. (2000meters) maximum.
Over voltage .............................. Category III 600V.
Battery ....................................... One 9V Battery.
Auto OFF ................................... approx. 15 minutes
Dimensions/Weight .................... 197x70x40mm/183g
For indoor use and in accordance with Overvoltage Category II, Pollution Degree 2. Category II includes local level, appliance,
portable equipment, etc., with transient overvoltages less than Overvoltage Cat. III
© Jack Sealey Ltd
1
2
Range
2.000AAC
20.00AAC
200.0AAC
400.0 AAC
200.0 mVDC
2.000 VDC
20.00 VDC
200.0 VDC
600.0 VDC
200.0 mVAC
2.000 VAC
20.00 VAC
200.0 VAC
600.0 VAC
200.0 Ω
2.000KΩ
20.00KΩ
200.0KΩ
2.000MΩ
20.00MΩ
" is displayed.
Original Language Version
4
6
7
8
10
Accuracy (% of reading)
± (2.5 % + 10 digits)
± (2.5 % + 4 digits)
± (2.5 % + 4 digits)
± (0.8% + 2 digits)
± (1.5% + 2digits)
± (2 % + 2 digits)
± (1.5% + 35 digits)
± (1.8% + 8 digits)
± (2.5% + 8 digits)
± (1.0% + 4 digits)
± (1.5% + 2 digits)
± (2.5% + 3 digits)
± (3.5% + 5 digits)
TM105
5
± (3 % + 4 digits)
Issue No: 2(I) - 17/06/14