Download Print this page

Specification; Resolution Accuracy - Sealey TA203.V2 Instructions Manual

Digital automotive analyser 15 function bar graph/pc link

Advertisement

3.

SPECIFICATION

DC Voltage (Auto Ranging)
Range
Resolution
400.0mV
0.1mV
4.000V
1mV
40.00V
10mV
400.0V
100mV
1000V
1V
Input Impedance: 10MΩ.
Maximum Input 700Vac rms or 1000Vdc.
AC Voltage (Auto Ranging except 400mV)
Range
Resolution
400.0mV
0.1mV
4.000V
1mV
40.00V
10mV
400.0V
100mV
750V
1V
Input Impedance: 10MΩ.
Frequency Range: 50 to 400Hz.
Maximum Input: 750Vac rms or 100Vdc.
Capacitance (Auto Ranging)
Range
Resolution
40.00nF
10pF
400.0nF
0.1nF
4.000uF
1nF
40.00uF
10nF
100.0uF
0.1uF
Input Protection: 250Vac rms or 250Vdc.
Resistance (Auto Ranging)
Range
Resolution
400.0Ω
0.1Ω
4.000kΩ
1Ω
40.00kΩ
10Ω
100Ω
400.0kΩ
4.000MΩ
1kΩ
40.00MΩ
10kΩ
Input Protection: 250Vac rms or 250Vdc.
Diode test
Range
Resolution
0.3mA typical
1mV
Open Circuit Voltage: 1.5Vdc typical
Overload Protection: 250Vac rms or dc.
Temperature
Range
Resolution
-20°C~+760°C 1°C
-4°F~+1400°F
1°F
Sensor: Type K Thermocouple
RPM (Tach)
Range

Resolution Accuracy

RPM 4 600~4000RPM
1RPM
600~1200RPM
10RPM
(X 10PM)
RPM 2 300~4000 RPM
1RPM
300~600RPM
10RPM
(x 10RPM)
Effect Reading: >600RPM
Overload Protection: 250Vac rms or dc.
Overvoltage Category:
CAT.111. 1000V.
RS232: Optically isolated PC interface cable and Windows® 95/98/200/XP compatible software to collect, display, plot and save data.
Display: 4 3.4 digit (4000 counts) LCD display with function and unit sign annunciator.
Analogue Bar Graph: 40 segments with measurements 15 times per second.
Polarity: Automatic, (-) negative polarity indication.
Over Range Indication: "OL" mark indication.
Low Battery Indication: The
Auto Power Off: Meter automatically shuts down after approx. 30 minutes of inactivity.
Measurement Rate: 2 times per second, nominal.
Operating Environment: 0°C to 50°C (32°F to 122°F) at <70% relative humidity.
Storage Environment: -20°C to 60°C (14°F to 140°F) at <80% relative humidity.
Temperature Coefficient: 0.2 x (specified accuracy) / °C (< 18°C or > 28°C.
Power: Single standard 9 Vollt battery ( PP9 ).
Battery Life: 200 hours typical with alkaline battery.
Fuse: 20A/250V, 10.3 x 38mm fast acting ceramic type.
0.5A/250V, 5 x 20mm fast acting ceramic type.
Dimensions: 197 (H) x 88.4 (W) x 41.2 (D) mm.
Weight Approx: 635g including holster.
Accuracy is given at 18°C to 28°C (65°F to 83°F) less than 70% relative humidity.
Accuracy
± 0.5% of reading ± 2 digits
±1.5% of reading ± 2 digits
± 1.8% of reading ± 2 digits
Accuracy
± 1.5% of reading ± 60 dig
± 1.0% of reading ± 3 digits
± 1.5% of reading ± 3 digits
± 2.0% of reading ± 4 digits
Accuracy
± 5.0% of reading ± 7 digits
± 3.0% of reading ± 5 digits
± 5.0% of reading ± 5 digits
Accuracy
± 1.2% of reading ± 4 digits
± 1.0% of reading ± 2 digits
± 1.2% of reading ± 2 digits
± 2.0% of reading ± 3 digits
Accuracy
± 10% of reading ±5 digits
Accuracy
± 3.0% of reading ± 5 digits
(Meter only, probe accuracy
not included).
±2% of rdg ± 4 digits
is displayed when the battery voltage drops below the operating level.
Duty Cycle (Auto Ranging)
Range
Resolution
0.1%~99.9%
0.1%
Pulse Width: >100us, <100ms
Sensitivity: < 0.5V rms
Overload Protection: 250Vac rms or dc.
Dwell Angle
Cylinder Range
Resolution
1CYL
0~360.0°
2CYL
0~180.0°
3CYL
0~120.0°
4CYL
0~90.0°
5CYL
0~72.0°
0.1°
6CYL
0~60.0°
8CYL
0~45.0°
10CYL
0~36.0°
12CYL
0~30.0°
Overload Protection: 250Vac rms or dc.
Frequency (Auto Ranging)
Range
Resolution
5Hz
0.001Hz
50Hz
0.01Hz
500Hz
0.1Hz
5kHz
1Hz
30.00kHz
10Hz
Sensitivity: >5V RMS MIN.
Overload Protection: 250Vac rms or dc.
DC Current (Auto Ranging for uA and mA)
Range
Resolution
400.0uA
0.1uA
4000uA
1uA
40.00mA
10uA
400.0mA
100uA
4A
1mA
20A
10mA
Overload Protection: 0.5A/250V and 20A/250V Fuse.
Maximum Input:400mAac rms or 400mAdc on uA/mA ranges
20A ac rms or dc on 10A range.
Pulse Width
Range
Resolution
2.0~10.0ms
0.1ms
Overload Protection: 250Vac rms or dc.
Audible Continuity
Audible threshold:
Less than 150Ω
Test Current:
<0.3mA
Overload Protection:
250Vac rms or dc.
AC Current (Auto Ranging for uA and mA
Range
Resolution
400.0uA
0.1uA
4000uA
1uA
40.00mA
10uA
400.0mA
100uA
4A
1mA
20A
10mA
Overload Protection: 0.5A/250V and 20A/250V Fuse.
Frequency Range:50 to 400Hz
Maximum Input: 40mA ac rms or 400mA dc on uA/mA ranges,
20A ac rms or dc on 20A range.
Accuracy
± 1.2% of reading ± 4 digits
Accuracy
± 2.0% of reading ± 4 digits
Accuracy
± 1.5% of reading ± 5 digits
± 1.2% of reading ± 3 digits
Accuracy
± 1.0% of reading ± 3 digits
± 1.5% of reading ± 3 digits
± 2.5% of reading ± 5 digits
Accuracy
± 3% of reading ± 10 digits
Accuracy
± 1.5% of reading ± 5 digits
± 3.0% of reading ± 7 digits
± 2.5% of reading ± 7 digits
TA203.V2 - 1 - 200807

Advertisement

loading

This manual is also suitable for:

Ta203