Paint thickness gauge

Advertisement

Quick Links

TA090
PAINT
THICKNESS
GAUGE
Original Language Version
© Jack Sealey Limited
TA090
Issue No.1 25/10/12

Advertisement

Table of Contents
loading

Summary of Contents for Sealey TA090

  • Page 1 TA090 PAINT THICKNESS GAUGE Original Language Version © Jack Sealey Limited TA090 Issue No.1 25/10/12...
  • Page 2: Safety Instructions

    TA090 MODEL No: Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS &...
  • Page 3: Operation

    TXT or CSV extension for exporting to spreadsheet programs. The GRAPH selection offers TREND or HISTOGRAM graph styles; a TREND graph is shown on the next page and a HISTOGRAM above. Original Language Version © Jack Sealey Limited TA090 Issue No.1 25/10/12...
  • Page 4: General Information

    Click this button to toggle the units of measurement used on the data graphs. 10. GENERAL INFORMATION The TA090 coating thickness gauge works either on the magnetic induction principle or on the eddy current principle. You can select either probe function via the MENU system. There is also an option to choose the probe function automatically.
  • Page 5 The TA090 gauge is suitable for laboratory, workshop and outdoor use. The probe can work on two principles, either magnetic induction or the eddy current principle. One probe only is required for coating measurement both on ferrous and non-ferrous metal substrates.
  • Page 6 3. Raise the lid of the compartment. 4. Remove battery. 5. Insert new battery. 6. Close the lid and refasten with screw. Caution: Ensure the polarity is correct when placing the batteries. Original Language Version © Jack Sealey Limited TA090 Issue No.1 25/10/12...
  • Page 7: Controls & Features

    8. Indicates the probe working or backlight ON/OFF In mode i.e. AUTO, Magnetic working mode. 16. Down/Right key. induction or Eddy current. 9. Low battery. 17. Zero Calibration key. Original Language Version © Jack Sealey Limited TA090 Issue No.1 25/10/12...
  • Page 8: Menu System

    LCD. Via the “statistic view” item in MENU system, you can look through all the statistical readings for the current group. © Jack Sealey Limited Original Language Version TA090...
  • Page 9 >>Limit settings >>>High limit >>>Low limit >>Delete limit MENU >Delete >>Current data >>All data >>Group data MENU >Measurement view MENU >Calibration >>Enable >>Disable >>Delete Zero N >>Delete Zero F © Jack Sealey Limited Original Language Version TA090 Issue No.1 25/10/12...
  • Page 10: Total Reset

    13.5 If the gauge is switched on whilst holding the probe away from the test object, it will initiate in DIRECT mode and the last reading will be shown (if available). Original Language Version © Jack Sealey Limited TA090 Issue No.1 25/10/12...
  • Page 11: Calibration & Measurement

    “y” means “there is Zero calibration”. “Cal 1~2” means” There is One or Two point Calibration”. After finishing all Calibration tasks, we advise that you disable calibration via the MENU system. Original Language Version © Jack Sealey Limited TA090 Issue No.1 25/10/12...
  • Page 12 14.9.3 Repeat the above step . 14.9.4 Take readings by placing the probe on the coating to be measured and raise it after the beep. The reading is shown on the display. Original Language Version © Jack Sealey Limited TA090 Issue No.1 25/10/12...
  • Page 13 Coating Thickness D =X±s±u Example: Readings: 150um, 156um, 153um Mean value: X=153um Standard deviation: s=±3um Measuring uncertainty: u=±(1% of reading + 1um) D= 153±3±(1,53um+1um) =153±5,5um MAX: maximum reading MIN: minimum reading Original Language Version © Jack Sealey Limited TA090 Issue No.1 25/10/12...
  • Page 14: Limit Function

    In this case the word “FULL” will be shown on the LCD in single measuring mode. In DIRECT mode, if the memory is full. The newest reading will replace the oldest reading. And the statistics will be updated. Original Language Version © Jack Sealey Limited TA090 Issue No.1 25/10/12...
  • Page 15: Troubleshooting

    BATTERY DISPOSAL / REPLACEMENT INFORMATION See Section 11.2 regarding battery access/ replacement. Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack Sealey Ltd’s Batteries Producer Registration Number (BPRN) is BPRN00705 NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.