2. INTRODUCTION & SPECIFICATION
INTRODUCTION: Includes new generation, 15-function, auto-ranging automotive diagnostic multimeter with Ir thermometer attachment. combination digital/
bar-graph display gives accurate indication of component outputs. Large, easy to read high contrast display with bright, white backlight. Workshop-tough, durable
bi-composite case with integral stand and auto power shut-off. High speed processing circuitry reads standard automotive parameters including duty cycle and
pulse width making this tool ideal for testing fuel injection systems. features auto-ranging, and data hold functions with overload protection on all ranges. Includes
relative functions including Min/Max and Peak Hold. supplied with Inductive coupler, Ir thermometer, test probes and thermocouple in carry case.
SPECIFICATION: ..................................................................Model No: TA304
tach (rPM): ........... 2-10cyl, 4-stroke 600-4000 (x1)rpm, 600-12000 (x10)rpm
Dwell: ...................................................................................................4/5/6/8cyl
Ac Voltage: ............................................................ 400mV, 4V, 40, 400V,
Dc Voltage: .......................................................... 400mV, 4V, 40, 400V,
Ac current: ....................................... 400µA, 4000µA, 40mA, 400mA, 4A, 20A
Dc current: ....................................... 400µA, 4000µA, 40mA, 400mA, 4A, 20A
capacitance:................................. 40nf, 400nf, 4µf, 40µf, 400µf, 4mf, 40mf
frequency:............................................................................. 0.001Hz-9.99MHz
Duty cycle: .........................................................................................0.1-99.9%
Pulse Width: ........................................................................................ 0.1-10ms
resistance: ...........................................400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
continuity:........................................................... <30Ω Continuity Buzzer 2kHz
temperature: ....................................................... -20 to +760°c, -4 to +1400°f
3. MAIN METER FEATURES
fig.1
© Jack sealey Limited
Ir temperature: ..................................................... -20 to +280°c, -4 to +536°f
Diode check: ................................................................................................ Yes
Back Light: .................................................................................................... Yes
700V
Bar Graph Display: ....................................................................................... n/A
1000V
Display Hold: ................................................................................................ Yes
Auto ranging: ............................................................................................... Yes
Inductive coupler: ........................................................................................ Yes
Digits Height: ............................................................................................ 20mm
Auto Power off: ............................................................................................ Yes
Low Battery Indicator:................................................................................... Yes
Batteries (supplied): ............................................................................ 9V (PP3)
Hi-Impact case: ............................................................................................ Yes
size (L x W x D): .................................................................... 182 x 82 x 55mm
Weight: ....................................................................................................... 360g
Original Language Version
fig.2
tA304 Issue:4(I) - 17/06/14