MASTER PASSWORD
HARD LOCK (ADMIN/PASS) ACCESS LIMITATIONS
A master password protection access limitation feature has been designed to allow a user logged in with
a master password the ability to define a wide range of mixer access limitations for other connected users
(without knowledge of the password. ie not logged in).
Enabling MASTER PASSWORD PROTECTION:
- Go to SETTINGS-->ACCESS tab page
- Select the ENABLE button
- Set a master password of your choice to enable MASTER PASSWORD PROTECTION
Note: Enabling MASTER PASSWORD PROTECTION will automatically log a user in.
Disabling MASTER PASSWORD PROTECTION:
- Go to SETTINGS-->ACCESS tab page
- Select the DISABLE button
- Enter the master password to disable MASTER PASSWORD PROTECTION
Logging in and configuring ALLOW CLIENT ACCESS FOR:
A logged in user can define GLOBAL client access limitations for non logged in users by allowing access to
certain parts of the mixer as defined below:
AUX LEVELS - AUX PROCESSING - MIX LEVELS - MIX PROCESSING - MIX GAIN - PLAYER - MASTER
LEVEL - MASTER PROCESSING - SHOWS - GLOBAL SETTINGS
LOCAL AUX CONTROL (SOFT ACCESS ENABLER)
A local client soft access eabler for AUX control is provided for non logged in users. The user can define
which AUX's they want to control if the master pass user has allowed access for either AUX LEVELS or
AUX PROCESSING.
Resetting a lost MASTER PASSWORD:
To reset a lost master password the user can connect a USB drive with an empty file named masterpass.txt
(top directory) and power cycle the unit with the RESET button on the side of the unit depressed. Hold the
RESET button dpressed state until the blue WiFi led on the top pannel stops flashing.The Master Password
will be reset.