Thank you for choosing an Iwaki’s EH-E Series metering pump. This instruction manual deals with the correct installation, operation, maintenance, and troubleshooting procedures for the EH-E model metering pump. Please read through it carefully to ensure the optimum performance, safety and service of your pump.
Important Instruction For the Safe and Correct Handling of the Pump Read the "Safety Instructions" sections carefully to prevent accidents involving your customers or other personnel and to avoid damage or loss of other assets. Always follow the instructions and advice found in these sections. Observe and abide by the instructions described in this manual.These instructions are very important for protecting pump users from dangerous conditions and situations related with the use of the pump system....
Prohibited No remodeling ! ! ! ! Never remodel a pump .Otherwise ,a serious accident may result.Iwaki will not be responsible for any accident or damage of any kind which is caused by the user remodeling the pump without first obtaining permission or instructions from No remodeling lwaki ....
Page 5
Safety Section Caution. Qualified operators only! ! ! ! The pump operator and pump operation supervisor must not allow any operators who have little or no knowledge of the pump to run and operate the pump . Pump operators must have a sound knowledge of the pump and its operation. Prohibited Specified power only....
Page 6
Safety Section Caution. Arrange grounding! ! ! ! Do not operate the pump without connecting the grounding wire. Otherwise, an electrical shock may result . Make sure the grounding wire is connected with grounding terminal. Grounding Install an earth leakage breaker (option)! ! ! ! The operation of a pump without using an earth leakage breaker may cause an electrical shock .
1.Unpacking After unpacking the goods, check the following points to ascertain that the product is exactly as you ordered. If you find anything wrong, please get in touch with your dealer. (1) Do the model, voltage, etc., shown on the nameplate represent what you ordered? (2) Has the goods been damaged in transit? Are the bolts and nuts loose?
3.Specifications Pump identification ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ① Series name EH Series ② Drive component E : 48 W ③ Diaphragm effective diameter 30:30mm 35:35mm 45:45mm 55:55mm ④ Material of liquid end Symbol Pump head Valve Balls Valve seat &...
Page 10
⑥ Power code with plug No symbol without plug ⑦ Controller E : E type ⑧ Connection Applicable hose dia. (ID×OD) Symbol Type φ 8 × φ 13 (mm) VC,V6,PC,VM φ 9 × φ 12 (mm) VC,V6,PC,VM φ 10 × φ 12(mm) φ...
Pump specifications Output Output per Maximum Stroke Stroke Model capacity Stroke Pressure frequency (spm) length % (ml/min) (ml/stroke) (MPa) (mm) 0.19~0.94 0.29~1.44 35(SH) 0.7(0.6) 20~100 0~360 0.42~2.08 (0.3~1.5mm) 0.69~3.47 1250 Note 1. The performance data is based on clean water at 25℃ under rated voltage. Note 2.
1. Before Use Operators and maintenance service staff must read the instruction manual thoroughly before using the products.Do not operate the pump system unless all of the contents in the manual are completely understood. Caution. Turn off the power supply. . . . Working without disconnecting the power supply may cause an electrical shock.
2. Location Choose a location for the pump which is clean, dry, close to an electrical outlet, and allows convenient access to stroke length control, frequency control, and tubing connections. Avoid areas where ambient temperature exceeds 40℃ or falls below 0℃, or where the pump or tubing would be exposed to direct sunlight.
4. Discharge tubing The discharge tubing run is less critical and can be any length required to reach the application point. Avoid sharp bends or kinks in the tubing and protect the tubing from sharp edges that could chafe or cut it.
1. Priming Caution. Do not operate the pump with discharge-side valve completely closed. Operating the pump with discharge-side valve fully closed may lead to liquid leakage or pipe rupture. Do not run pump dry. Dry operation of the pump over a long time (longer than 30 minutes) causes the pump to overheat and the pump unit (pump head, valve guide etc.) to become deformed or the pump head attachment to become loose, which may result in liquid leakage trouble.
2. Adjustment The pump will operate best with the stroke length at 100%. It is recommended to get required flow rate by adjusting frequency control. Example: Model EH-E30VC has maximum output of 340 ml/min. Required output is 255 ml/min. 255÷340 = 0.75 or 75 %.
4.External Control 4.1 Display/Keypad and Wiring Overview UP key. Alpha/numeric display. Start/Stop Key. Indicates stroke frequency, Manually starts or stops the Increases numeric values. Is pump. This key is used in setting external mode or external settings. used with EXT key to select external modes.
4.External Control 4.2 Quick Reference =Start/Stop key =EXT[ternal]key EHE Quick reference Guide From: Press run in manual mode WAIT ▼ decrease frequency (360 to 1 spm ) ▲ increase frequency (1 to 360 spm ) ▲ external mode ▼ external values ▼...
Page 25
4.External Control 4.2 Quick Reference Mode Change and Operation of Keys Power ON Indication of version V2.2 WAIT WAIT WAIT WAIT Stand-by mode start start start start start stop stop stop stop stop ▲ ▼ Set External Set External Manual External Mode Values...
4.External Control 4.3 Digital Mode 4-2.Set mu1tip1y or divide To set values for digital operation, press EXT and ▼ simultaneously. The display will show / or X and a 3 digit number. Now pressing the EXT button will alternate between X (multiply) and / (divide). 4-3.Set the value ▲...
4.External Control 4.4 Analog Mode 4.4Analog Mode. In analog mode the pump will accept a milliamp signal and produce a pump speed proportional to the signal level received. Signal ranges of 4-20, 0-20,20-4 or 20-0 can be selected. 1.Connecting an analog signal device Disconnect AC power to the pump.
Page 29
STOP Function The EH-E series pump also includes a STOP function which allows an external signal to stop the operation of the pump. A switch or solid state device capable of switching 5 VDC at 2 mA can be connected to terminals 6 (positive) and 8 (negative) of the terminal block.
4.External Control 4.5 AC Power Interruption If AC power is interrupted and then returned, the functions return as shown below. State before power is interrupted State after power returned WAIT WAIT Run manual Run manual Run external Run external Set EXTernal mode WAIT Set EXTernal values WAIT...
1. Maintenance Caution Before working on the pump, disconnect the power cord, depressurize the discharge tubing and drain or flush any residual liquid from the pump head and valves. 2.Diaphragm Replacement Disconnect AC power to the pump and disconnect the suction tubing and discharge tubing.
5. Names of Part and Structure (1)Pump Head Unit(Material symbol:VC/V6/PC/P6/VM/FC) - 31 -...
Page 34
5. Names of Part and Structure (2)Pump Head Unit(Material symbol: SH) E30/E35/E45 - 32 -...
Page 35
5. Names of Part and Structure (3)Pump Head Unit (Material symbol: SH) - 33 -...
Page 36
Parts name of pump head No. Parts name for types VC/V6/PC/VM/FC Parts name for type SH 1 Pump head 1 Pump head 3 Fitting 3 Suction fitting 4 Fitting nut 4 Discharge fitting 7 Diaphragm 7 Diaphragm 9 Retainer 9 Retainer 10 Back up retainer 11 Valve guide 11 Valve guide...
1. Troubleshooting Caution Before working on the pump, disconnect the power cord, depressurize the discharge tubing and drain or flush any residual liquid from the pump head and valves. Problem Possible Cause Corrective Action Pump does not start Faulty wiring Correct wiring Improper voltage Connect to proper voltage source...