Balluff BES M30EP-PFC12F-S04G-D12 User Manual page 16

Table of Contents

Advertisement

BES M/Q...-D12 Inductive Safety Sensors
Observe the following conditions::
Take measures which prevent metallic objects from unknowingly
contacting the active surface.
For interlocking devices together with guards observe
DIN EN ISO 14119.
Maintain specified application conditions (see Section Technical
Data on page 36).
Use of the sensor in the vicinity of chemical and biological media
as well as ionizing radiation is not permitted.
Maintain the rest current principle for all safety circuits connected
externally to the system.
For faults within the safety sensor which result in a change to
the condition defined as safe: Take measures which maintain the
safe condition for continued operation of the host controller.
Replace damaged devices.
Functional impairments
In the event of defects and device malfunctions that cannot be
rectified, the device must be immediately taken out of operation and
protected against unauthorized use.
Intended use is ensured only when the housing is fully installed.