APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 50 of 68)
ADDR
REGISTER NAME
B0B5
Include non-IEC 61850 Data
B0B6
IEC 61850 Server Data Scanning Function
B0B7
IEC 61850 LPHD Latitude
B0B9
IEC 61850 LPHD DC PhyNam Longitude
B9BB
IEC 61850 LPHD DC PhyNam Altitude
B0BD
Reserved (3 items)
IEC 61850 MMXU Deadbands (Read/Write Setting) (6 modules)
B0C0
IEC 61850 MMXU TotW Deadband 1
B0C2
IEC 61850 MMXU TotVAr Deadband 1
B0C4
IEC 61850 MMXU TotVA Deadband 1
B0C6
IEC 61850 MMXU TotPF Deadband 1
B0C8
IEC 61850 MMXU Hz Deadband 1
B0CA
IEC 61850 MMXU PPV.phsAB Deadband 1
B0CC
IEC 61850 MMXU PPV.phsBC Deadband 1
B0CE
IEC 61850 MMXU PPV.phsCA Deadband 1
B0D0
IEC 61850 MMXU PhV.phsADeadband 1
B0D2
IEC 61850 MMXU PhV.phsB Deadband 1
B0D4
IEC 61850 MMXU PhV.phsC Deadband 1
B0D6
IEC 61850 MMXU A.phsA Deadband 1
B0D8
IEC 61850 MMXU A.phsB Deadband 1
B0DA
IEC 61850 MMXU A.phsC Deadband 1
B0DC
IEC 61850 MMXU A.neut Deadband 1
B0DE
IEC 61850 MMXU W.phsA Deadband 1
B0E0
IEC 61850 MMXU W.phsB Deadband 1
B0E2
IEC 61850 MMXU W.phsC Deadband 1
B0E4
IEC 61850 MMXU VAr.phsA Deadband 1
B0E6
IEC 61850 MMXU VAr.phsB Deadband 1
B0E8
IEC 61850 MMXU VAr.phsC Deadband 1
B0EA
IEC 61850 MMXU VA.phsA Deadband 1
B0EC
IEC 61850 MMXU VA.phsB Deadband 1
B0EE
IEC 61850 MMXU VA.phsC Deadband 1
B0F0
IEC 61850 MMXU PF.phsA Deadband 1
B0F2
IEC 61850 MMXU PF.phsB Deadband 1
B0F4
IEC 61850 MMXU PF.phsC Deadband 1
B0F6
...Repeated for Deadband 2
B12C
...Repeated for Deadband 3
B162
...Repeated for Deadband 4
B198
...Repeated for Deadband 5
B1CE
...Repeated for Deadband 6
IEC 61850 Received Analogs (Read Only) (32 modules)
B210
IEC 61850 Received Analog 1
B212
...Repeated for Received Analog 2
B214
...Repeated for Received Analog 3
B216
...Repeated for Received Analog 4
B218
...Repeated for Received Analog 5
B21A
...Repeated for Received Analog 6
B21C
...Repeated for Received Analog 7
B21E
...Repeated for Received Analog 8
B220
...Repeated for Received Analog 9
B222
...Repeated for Received Analog 10
B224
...Repeated for Received Analog 11
B226
...Repeated for Received Analog 12
B228
...Repeated for Received Analog 13
GE Multilin
RANGE
0 to 1
0 to 1
-90000 to 90000
-180000 to 180000
0 to 10000
0 to 1
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
-1000000000000 to
1000000000000
T60 Transformer Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
1
F102
degree
0.001
F060
degree
0.001
F060
m
1
F060
---
1
F001
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
---
0.001
F060
DEFAULT
0 (Disabled)
0 (Disabled)
0
0
0
B
0
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
0