GE t60 Instruction Manual page 566

Ur series transformer protection system
Hide thumbs Also See for t60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 37 of 68)
ADDR
REGISTER NAME
7925
PMU Ic Calibration Angle
7926
PMU Ic Calibration Magnitude
7927
PMU Ig Calibration Angle
7928
PMU Ig Calibration Magnitude
7929
PMU Sequence Voltage Shift Angle
B
792A
PMU Sequence Current Shift Angle
Phasor Measurement Unit Triggering (Read/Write Setting) (4 modules)
7970
PMU 1 User Trigger
Phasor Measurement Unit Current Trigger (Read/Write Setting) (4 modules)
7980
PMU 1 Current Trigger Function
7981
PMU 1 Current Trigger Pickup
7982
PMU 1 Current Trigger Pickup Time
7983
PMU 1 Current Trigger Dropout Time
7984
PMU 1 Current Trigger Block (3 items)
798A
PMU 1 Current Trigger Target
798B
PMU 1 Current Trigger Events
Phasor Measurement Unit df/dt Trigger (Read/Write Setting)
79B0
PMU 1 df/dt Trigger Function
79B1
PMU 1 df/dt Trigger Raise
79B2
PMU 1 df/dt Trigger Fall
79B3
PMU 1 df/dt Trigger Pickup Time
79B4
PMU 1 df/dt Trigger Dropout Time
79B5
PMU 1 df/dt Trigger Block (3 items)
79BB
PMU 1 df/dt Trigger Target
79BC
PMU 1 df/dt Trigger Events
Underfrequency (Read/Write Setting) (6 modules)
7A80
Underfreqency Function
7A81
Underfrequency Block
7A83
Min Current
7A84
Underfrequency Pickup
7A85
Pickup Delay
7A86
Reset Delay
7A87
Underfrequency Source
7A88
Underfrequency Events
7A89
Underfrequency Target
7A8A
Underfreqency 1 Reserved (5 items)
7A8F
...Repeated for Underfrequency 2
7A9E
...Repeated for Underfrequency 3
7AAD
...Repeated for Underfrequency 4
7ABC
...Repeated for Underfrequency 5
7ACB
...Repeated for Underfrequency 6
User Programmable Pushbuttons (Read/Write Setting) (16 modules)
7B60
User Programmable Pushbutton 1 Function
7B61
User Programmable Pushbutton 1 Top Line
7B6B
User Programmable Pushbutton 1 On Text
7B75
User Programmable Pushbutton 1 Off Text
7B7F
User Programmable Pushbutton 1 Drop-Out Time
7B80
User Programmable Pushbutton 1 Target
7B81
User Programmable Pushbutton 1 Events
7B82
User Programmable Pushbutton 1 LED Operand
7B84
User Programmable Pushbutton 1 Autoreset Delay
7B85
User Programmable Pushbutton 1 Autoreset Function
7B86
User Programmable Pushbutton 1 Local Lock
7B88
User Programmable Pushbutton 1 Message Priority
B-44
RANGE
-5 to 5
95 to 105
-5 to 5
95 to 105
-180 to 180
-180 to 180
0 to 4294967295
0 to 1
0.1 to 30
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 1
0.1 to 15
0.1 to 15
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 4294967295
0.1 to 1.25
20 to 65
0 to 65.535
0 to 65.535
0 to 5
0 to 1
0 to 2
0 to 1
0 to 2
---
---
---
0 to 60
0 to 2
0 to 1
0 to 4294967295
0 to 600
0 to 1
0 to 4294967295
0 to 2
T60 Transformer Protection System
APPENDIX B
UNITS
STEP
FORMAT
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
30
F002
°
30
F002
---
1
F300
---
1
F102
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
Hz/s
0.01
F001
Hz/s
0.01
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F300
pu
0.01
F001
Hz
0.01
F001
s
0.001
F001
s
0.001
F001
---
1
F167
---
1
F102
---
1
F109
---
1
F001
---
1
F109
---
---
F202
---
---
F202
---
---
F202
s
0.05
F001
---
1
F109
---
1
F102
---
1
F300
s
0.05
F001
---
1
F102
---
1
F300
---
1
F220
DEFAULT
0
1000
0
1000
0
0
0
0 (Disabled)
1800
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
25
25
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0
10
5950
2000
2000
0 (SRC 1)
0 (Disabled)
0 (Self-reset)
0
2 (Disabled)
(none)
(none)
(none)
0
0 (Self-reset)
0 (Disabled)
0
0
0 (Disabled)
0
0 (Disabled)
GE Multilin