  • Page 1  USER GUIDE SMARC sXAL Doc. Rev. 1.0 Doc-ID: 1061-8306...
  • Page 2 Kontron with respect to technical processes described in the manual or any product characteristics set out in the manual. Kontron assumes no responsibility or liability for the use of the described product(s), conveys no license or title under any patent, copyright or mask work rights to these products and makes no representations or warranties that these products are free from patent, copyright or mask work right infringement unless otherwise specified.
  • Page 3: Revision History

    If you have any difficulties using this user guide, discover an error, or just want to provide some feedback, contact Kontron support. Detail any errors you find. We will correct the errors or problems as soon as possible and post the...
  • Page 4 Kontron sells products worldwide and declares regional General Terms & Conditions of Sale, and Purchase Order Terms & Conditions. Visit http://www.kontron.com/terms-and-conditions. For contact information, refer to the corporate offices contact information on the last page of this user guide or visit...
  • Page 5: Symbols

    SMARC sXAL User Guide. Rev. 1.0 Symbols The following symbols may be used in this manual DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 6 Therefore, in the interest of your own safety and of the correct operation of your new Kontron product, you are requested to conform with the following guidelines.
  • Page 7 General Instructions on Usage In order to maintain Kontron’s product warranty, this product must not be altered or modified in any way. Changes modifications to the product, that are not explicitly approved by Kontron and described in this User Guide or received from Kontron’s Technical Support as a special handling instruction, will void your warranty.
  • Page 8: Table Of Contents

    Figure 2: Top View ......................................16 Figure 3: Front View ......................................16 Figure 4: Back View ......................................16 Figure 5: Rear Side from SMARC sxal ................................ 17 Figure 6: Mechanical Drawing from SMARC sxal ..........................17 Figure 7: Heatspreader as cooling solution ............................. 18 Figure 8: 3-pin Fan Connector ..................................
  • Page 9: 1/ Introduction

    SMARC sXAL User Guide. Rev. 1.0 1/ Introduction This manual describes the Smart Mobility ARChitecture (SMARC) sxal board. The use of this Users Guide implies a basic knowledge of PC hard- and software. This manual is focussed on describing the special features and is not intended to be a standard PC textbook.
  • Page 10: 2/ Description

    SMARC sXAL User Guide. Rev. 1.0 2/ Description The SMARC sxal is a SMARC half-size module using the Intel Apollo Lake-I processor based on Intel x86 SoC. It is designed on the latest SMARC 2.0 specification. Figure 1: Half-size Card with SMARC interface Main characteristics are: ...
  • Page 11: 3/ Installation Procedure

    SMARC sXAL User Guide. Rev. 1.0 3/ Installation procedure 3.1. Packing Check List The package includes the following basic items accompany with this manual.  One board If this item is damaged or missed, please contact your vendor and save all packing materials for future replacement and maintenance.
  • Page 12: 4/ System Specifications

    Temperature measurement of the SMARC PCB (2x with external thermal diode)  A/D measurements on V_RTC, V_3V3_S0 and V_3V0-525_IN Trusted Platform incorporated Module (TPM) Complex The SMARC sxal design shall incorporate a Altera MAX10 CPLD controller which will handle Programmable the following. Logic Devices  Power Sequencing (CPLD) ...
  • Page 13 Hardware Monitor chip. Power one 10-pin power connector: The SMARC sxal is supplied from a single power supply supporting a voltage of 5 V. The SMARC specification defines a maximum current per input voltage pin of 0.5 A.
  • Page 14: Table 2: Environmental Conditions

    SMARC sXAL User Guide. Rev. 1.0 Security Kontron Security The board is equipped with the Kontron Security Solution Approtect, providing an Solution Approtect embedded hardware security solution that enables applications to be secured, even in unsecure environments. The solution provides features such as: ...
  • Page 15: 5/ Connectors

    SMARC sXAL User Guide. Rev. 1.0 5/ Connectors 5.1. Hardware Configuration Setting This chapter gives the definitions and shows the positions of jumpers, headers and connectors. All of the configuration jumpers on the board are in the proper position. The default settings shipped from factory are marked with an asterisk (*).
  • Page 16: Mainboard View And I/O Locations

    SMARC sXAL User Guide. Rev. 1.0 5.2. Mainboard view and I/O locations Figure 2: Top View Figure 3: Front View Figure 4: Back View Memory SMARC connector Sys Fan/CPU Fan CPLD...
  • Page 17: Rear Side

    SMARC sXAL User Guide. Rev. 1.0 5.3. Rear Side Figure 5: Rear Side from SMARC sxal 5.4. Mechanical Drawing Figure 6: Mechanical Drawing from SMARC sxal www.kontron.com // 17...
  • Page 18: Thermal Management, Heatspreader And Cooling Solutions

    5.5. Thermal Management, Heatspreader and Cooling Solutions A heatspreader plate assembly is available from Kontron for the SMARC sXCAL (2). The heatspreader plate on top of this assembly is NOT a heat sink. It works as a SMARC-standard thermal interface to use with a heat sink or external cooling devices.
  • Page 19: 6/ Pin Definitions

    SMARC sXAL User Guide. Rev. 1.0 6/ Pin Definitions The following sections provide pin definitions and detailed description of all on-board connectors. The connector definitions follow the following notation: Table 4: Connector Definitions Column Name Description Shows the pin-numbers in the connector. The graphical layout of the connector definition tables is made similar to the physical connectors.
  • Page 20: Processor Support

    SMARC sXAL User Guide. Rev. 1.0 6.1. Processor Support Kontron has defined the board versions as listed in the following table, so far all based on Embedded CPUs. Industrial Grade:  Intel Atom x5 E3930 2C 1.8 GHz, 6,5W (Entry SKU of Apollo Lake @ -40°C to 85°C) ...
  • Page 21: Fan Connector

    SMARC sXAL User Guide. Rev. 1.0 6.3. Fan Connector The FANSYS (SYS_FAN) can be used to power, control and monitor a fan for chassis ventilation etc. The three-pin header is recommended to be used for driving three-wire type Fan in order to implement Fan speed control.
  • Page 22: Cpld Programming Header

    SMARC sXAL User Guide. Rev. 1.0 6.4. CPLD programming header Figure 9: 6-pin CPLD Connector Signal 3.3V Supply...
  • Page 23: Smarc Connector

    SMARC sXAL User Guide. Rev. 1.0 6.5. SMARC Connector The SMARC connector has different pins on both sides:  Top side: 74 pins are on the left side, 82 pins on the right side  Bottom side: 75 pins are on the left side, 83 pins on the right side...
  • Page 24 SMARC sXAL User Guide. Rev. 1.0 P-Pin Signal S-Pin Signal GBE0_MDI3+ GBE1_MDI1+ GBE0_LINK100# GBE1_MDI1- GBE0_LINK1000# GBE1_LINK1000# GBE0_MDI2- GBE1_MDI2+ GBE0_MDI2- GBE1_MDI2- GBE0_MDI2+ GBE0_LINK_ACT# GBE1_MDI3+ GBE0_MDI1- GBE1_MDI3- GBE0_MDI1+ GBE1_CTREF GBE0_CTREF PCIE_D_TX+ GBE0_MDI0- PCIE_D_TX- GBE0_MDI0+ GBE1_LINK_ACT# SPI0_CS1# PCIE_D_RX+ PCIE_D_RX- SDIO_WP SDIO_CMD USB4+ SDIO_CD#...
  • Page 25 SMARC sXAL User Guide. Rev. 1.0 P-Pin Signal S-Pin Signal USB0_VBUS_DET USB0_OTG_ID USB3_SSRX+ USB1+ USB3_SSRX- USB1- USB1_EN_OC# USB3+ USB3- USB2+ USB2- USB2_SSTX+ USB2_EN_OC# USB2_SSTX- RSVD RSVD USB2_SSRX+ USB3_EN_OC# USB2_SSRX- PCIE_A_RST# PCIE_B_RST# USB4_EN_OC# PCIE_C_RST# RSVD PCIE_C_RX+ RSVD PCIE_C_RX- PCIE_C_REFCK+ PCIE_C_TX+ PCIE_C_REFCK-...
  • Page 26 SMARC sXAL User Guide. Rev. 1.0 P-Pin Signal S-Pin Signal P100 S101 P101 HDMI_CK+ / S102 DP0_LANE3+ DP1_LANE3+ P102 S103 DP0_LANE3- HDMI_CK- / DP1_LANE3- P103 S104 USB3_OTG_ID P104 S105 DP0_AUX+ HDMI_HPD / DP1_HPD P105 HDMI_CTRL_CK / S106 DP0_AUX- DP1_AUX+ P106...
  • Page 27 SMARC sXAL User Guide. Rev. 1.0 P-Pin Signal S-Pin Signal DSI0_D0+ P125 BOOT_SEL2# S126 LVDS0_0- / eDP0_TX0- / DSI0_D0- P126 RESET_OUT# S127 LCD0_BKLT_EN P127 RESET_IN# S128 LVDS0_1+ / eDP0_TX1+ / DSI0_D1+ P128 POWER_BTN# S129 LVDS0_1- / eDP0_TX1- / DSI0_D1- P129...
  • Page 28 SMARC sXAL User Guide. Rev. 1.0 P-Pin Signal S-Pin Signal P153 VDD_IN S154 CARRIER_PWR_ON P154 VDD_IN S155 FORCE_RECOV# P155 VDD_IN S156 BATLOW# P156 VDD_IN S157 TEST#...
  • Page 29: List Of Acronyms

    SMARC sXAL User Guide. Rev. 1.0 List of Acronyms CPLD Complex Programmable Logic Devices Camera Serial Interface embedded Display Port Electromagnetic Compatibility Electromagnetic Interference eMMC embedded Multimedia Card Electrostatic Discharge GPIO General-purpose input/output High Definition Audio HDMI Integrated High Definition Multimedia Interface...
  • Page 30: About Kontron

    Kontron is a listed company. Its shares are traded in the Prime Standard segment of the Frankfurt Stock Exchange and on other exchanges under the symbol “KBC”. For more information, please visit: http://www.kontron.com/...