PERIODIC INSPECTION AND ADJUSTMENT
JET PUMP UNIT
Clean-out cap inspection
1. Remove:
G
Clean-out cap 1
2. Inspect:
G
Rubber seal
Crack/Damage ➔ Replace.
G
Locking mechanism
Wear/Damage ➔ Replace
3. Install:
G
Clean-out cap
NOTE:
G
Align the projection of the clean-out cap
with the recess of the clean-out opening.
G
Holding the cap by the T handle, insert into
the opening until fully seated.
G
Firmly press the T handle till the cap locks
in place.
G
Firmly pull up on the T handle to verify the
cap has locked securely in place.
CAUTION:
Be sure the cap is properly positioned and
locked in place. Otherwise the cap could
loosen and be forced out of the access ports
by water pressure, causing loss of perfor-
mance and possible damage.
1 1
11
INSP
3