Storage Of New Low-Pressure And High-Pressure Stages - ABB Power2 800-M Original Assembly Instructions

Hide thumbs Also See for Power2 800-M:
Table of Contents

Advertisement

Assembly Instructions / Power2 800-M
6

Storage of new low-pressure and high-pressure stages

6
Storage of new low-pressure and high-
pressure stages
Storage of new low-pressure and high-pressure stages and cartridge groups for up to 6
months
New low-pressure and high-pressure stages and cartridge groups from ABB Turbo Systems
can be stored in their closed packages for 6 months from the date of delivery without addition-
al mothballing measures (indicated by VCI label on package).
Figure 10: Volatile Corrosion Inhibitor (VCI)
Only dry rooms with 40...70 % atmospheric humidity, in which no water condensation can
form, are suitable as storage locations.
Storage of new low-pressure and high-pressure stages and cartridge groups for more than 6
months (VCI)
Health protection when handling VCI
VCI products are not hazardous in terms of the Ordinance on Hazardous
Substances. Nevertheless, the following points must be observed when
WARNING
handling VCI:
Ensure proper space ventilation.
Do not eat, drink or store food at the workplace while working with VCI.
Wear safety gloves.
Clean hands and face after working with VCI.
For more information, see www.branopac.com.
Every 6 months, the following mothballing measures are required:
Open package.
Remove VCI corrosion protection emitter from package and replace with a new VCI corro-
sion protection emitter of the same kind. New VCI corrosion protection emitters can be ob-
tained from www.branopac.com.
Old VCI corrosion protection emitters must be disposed of in an environmentally compati-
ble, professional way and in compliance with locally applicable regulations.
Close package. The more tightly the package is sealed, the longer the protection duration.
© Copyright 2016 ABB. All rights reserved.
HZTL455311P0010
Page 18 / 21
Revision -
March 2016

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power2 850-m

Table of Contents