Trouble Criterion Of Main Parts - Mitsubishi Electric SUH-1.6VR2 Technical & Service Manual

Table of Contents

Advertisement

9-2. Trouble criterion of main parts

SUH-1VR.TH
SUH-1.6VR.TH
SUH-1.6VR2.TH
SU-1.6NR.TH
SU-1VR.TH
SU-1.6VR.TH
SU-1.6VR2.TH
SU-1VR.TH-T
SU-1.6VR.TH-T
SU-1.6VR2.TH-T
Part name
Measure the resistance with a tester.
(Part temperature 10°C ~ 40°C)
Defrost
thermistor
(Outdoor)
Measure the resistance between the terminal with a tester.
(Coil wiring temperature 10°C ~ 40°C)
Compressor
C-R
C-S
C-R
C-S
Measure the resistance between the terminals with a tester.
(Coil wiring temperature -10°C ~ 40°C)
Outdoor fan
motor
WHT-BLK
BLK-RED
BLK-YLW
YLW-RED
WHT-BLK
BLK-RED
BLK-YLW
SUH-2VR.TH
SUH-2VR
SUH-2VR
SU-2NR.TH
SU-2VR.TH
SU-2VR
SU-2VR.TH-T
SU-2VR
Check method and criterion
Normal
5kΩ~60kΩ
Opened or short-circuited
Normal
SUH-
1VR
1.6VR
1.6VR2
2.9~3.6Ω
1.9~2.3Ω
1.6~2.0Ω
5.1~6.3Ω
2.4~4.2Ω
2.6~3.2Ω
Normal
SU-
1
1.6
VR
NR
VR
VR2
2.9~
1.5~
1.9~
1.6~
3.6Ω
1.9Ω
2.3Ω
2.0Ω
5.1~
2.4~
3.4~
2.6~
6.3Ω
3.0Ω
4.2Ω
3.2Ω
Normal
SUH-
1VR
1.6VR, 1.6VR2
311~381Ω
115~141Ω
283~347Ω
118~146Ω
Normal
SU-
1
1.6
VR
NR, VR, VR2
311~381Ω
115~141Ω
283~347Ω
118~146Ω
SUH-2.5VR.TH
.TH
1
.TH
2
SU-2.5NR.TH
SU-2.5VR.TH
.TH
1
SU-2.5VR.TH-T
.TH-T
1
Abnormal
2VR, 2VR
, 2VR
2.5VR
1
2
0.9~1.2Ω
0.8~1.0Ω
short-circuited
2.0~2.4Ω
1.8~2.2Ω
2
2.5
VR, VR
NR
NR
VR
1
0.8~
0.9~
0.7~
0.8~
1.0Ω
1.2Ω
0.9Ω
1.0Ω
1.7~
2.0~
1.6~
1.8~
short-circuited
2.1Ω
2.4Ω
2.0Ω
2.2Ω
2VR, 2VR
, 2VR
2.5VR
1
2
102~126Ω
55~68Ω
98~120Ω
27~33Ω
short-circuited
55~68Ω
2
2.5
NR, VR, VR
NR, VR
1
102~126Ω
72~88Ω
98~120Ω
90~110Ω
short-circuited
81~99Ω
31
Figure
Abnormal
Opened or
WHT
C
S
RED
Abnormal
Opened or
1VR
MAIN
AUX
FUSE
Abnormal
BLK
RED
1.6, 2NR
1.6, 2VR
1.6VR2, 2VR
Opened or
MAIN
AUX
P
BLK
RED ORN WHT
Abnormal
SUH-2.5VR
MAIN
AUX.1
AUX.2
Opened or
BLK YLW RED ORN WHT
SU-2.5NR
SU-2.5VR
MAIN
AUX.1
AUX.2
P
YLW
BLK
RED ORN WHT
p
R
BLK
WHT
, 2VR
1
2
P
: Inner protector

Hide quick links:

Advertisement

Table of Contents
loading