[Sysname] openflow instance 1
[Sysname-of-inst-1] controller connect interval 10
controller echo-request interval
Use controller echo-request interval to set the connection detection interval for an OpenFlow switch. The
connection detection interval specifies the interval at which the OpenFlow switch sends an Echo Request
message to a controller.
Use undo controller echo-request interval to restore the default.
Syntax
controller echo-request interval interval-value
undo controller echo-request interval
Default
The connection detection interval is 5 seconds.
Views
OpenFlow instance view
Predefined user roles
network-admin
Parameters
interval-value: Specifies the connection detection interval in seconds, in the range of 1 to 10.
Examples
# Set the detection connection interval to 10 seconds for OpenFlow instance 1.
<Sysname> system-view
[Sysname] openflow instance 1
[Sysname-of-inst-1] controller echo-request interval 10
controller mode
Use controller mode to set the controller mode for an OpenFlow instance.
Use undo controller mode to restore the default.
Syntax
controller mode { multiple | single }
undo controller mode
Default
The controller mode is multiple.
Views
OpenFlow instance view
Predefined user roles
network-admin