Electrical System; Circuit Diagram For Xahs 146 Dd, - Atlas Copco XAHS 146 Dd Instruction Manual

Hide thumbs Also See for XAHS 146 Dd:
Table of Contents

Advertisement

Instruction Manual
2.8
E
LECTRICAL SYSTEM
2.8.1 C
IRCUIT DIAGRAM FOR
All compressors are equipped with a negative earthed system.
1
To be used with Cold Start Option.
2
To be used with Refinery Equipment.
3
Position of DIP-switches.
Fig. 2.5
Circuit diagram (Nr. 9822 0893 12)
B6
Fuel Level Sensor
F1
Circuit Breaker
G1
Battery 12V
G2
Charging Alternator
K0
Starter Solenoid
K5
Auxiliary Starter Relay
K6
Cold Start Relay
K9
Overspeed Relay
Note:
For correct functioning of the module, the dip switches at the back of the module should be positioned as follows
Fig. 2.6
Dip switches
XAHS 146 D
, XATS 156 D
D
M1
Starter Motor
N4
Control Module
N5
Overspeed Control Module
P1
Hourmeter
P2
Glowplug
P3
Fuel Level Gauge
S3
Compressor Temperature Switch
S4
Engine Temperature Switch
Standard (no coldstart)
Preheat-Coldstart
Low fuel level
Low coolant level
XA(S) 186 D
D AND
With coldstart option
Not used
D
S5
Engine Low Oil Pressure Switch
S7
Overspeed Control Test Switch
S8
Push Button
S9
Coolant Level Switch
X1
Module Connector
Y1
Fuel Stop Solenoid
Y2
Excess Fuel Provider
Y3
Overspeed Solenoid
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xahs 186 ddXats 156 ddXa(s) 186 ddXavs 166 dd

Table of Contents