3.2 Specifications

Approval:
Protection type
Approval
Protection category:
Housing:
Material
Dimensions
Weight
Environmental conditions during operation:
Temperature range
Humidity
Environmental conditions storage:
Temperature range
X1 data interface:
Data
Baudrate
Connector
Voltage U
n
X2 interface power supply:
Voltage U
n
Drawing of current
Fuse SI 1
Connector
TDOCT-4038_ENG / 2015-01
[EEx ib] IIC
DMT 03 ATEX E 011 X
IP 20
Aluminum
refer to chapter "Housing"
app. 1.0 kg
0 °C - + 50 °C
max. 85 % non-condensating (48 h stress test)
Warning
The ENT-DC may only be set up and operated in a
non-hazardous area.
-20 °C - +70 °C
20 mA CL active/passive, zero potential
RS232
19.200 Baud (38.000 Baud on request)
9-pin D-Sub integrated jack, pin contacts
≤ |±15| V DC
24 V DC ±10%
1 feed circuit:
app. 380 mA continuous current
2 feed circuits: appear. 550 mA continuous current
3 feed circuits: appear. 720 mA continuous current
is safety relevant. Always use the correct fuse type.
2A slow blowing (type H 1500 A)
2 x 2-pin integrated jack / pin contacts, for CONNECTOR-K02-381-O
6