1. Introduction
The F940WGOT series (hereafter called "GOT") is to be
mounted on the face of a control panel or operations panel, and
c o nn e ct e d t o t he pr o gra m m in g p or t ( CP U po r t ) o r t h e
communication port (communication units port) of a PLC.
Various devices can be monitored and PLC data changed
through the screens in the GOT. Several display screens are
built-in to the GOT, and additional personalized screens can be
created by the user.
1) The GOT can connect to MELSEC FX, A, QnA and Q PLCs
as well as a host of third party manufactured units. Further
information can be found in GOT-F900 Series Hardware
Manual.
2) Through the GOT, PLC user programs can be downloaded, uploaded and monitored in programming
software GX-Developer or FX-PCS/WIN-E on a personal computer. Further information can be found
in GOT-F900 Series Operation Manual.
3) Display screens are created using the following software.
Software Name
GT Designer
FX-PCS-DU/WIN-E

1.1 Product Lists

Production Name
F940WGOT-TWD-E
FX-50DU-CAB0
FX-50DU-CAB0/EN
FX-50DU-CAB0-**M
FX-40DU-CAB
FX-40DU-CAB-**M
QC30R2
FX-232CAB-1
PM-20BL
F9WGT-40PSC
F9GT-40FMB
Caution
During abnormal communication (including cable break) when monitor is executed within the
GOT, communication between the GOT and programmable controller CPU is interrupted and
it is impossible to operate switches or devices in the PLC through the GOT.
Communication and operation resumes when the GOT system is correctly configured.
DO NOT configure emergency stop or safety features to operate through the GOT, and be
sure that there is no adverse consequences in the event of a GOT - PLC communications
malfunction.
Note;
Do not lay signal cables near high voltage power cables or allow them to share the same
trunking duct.
Otherwise effects of noise or surge induction are likely to take please. Keep a safe
distance of more than 100 mm from these wires.
Operate touch switches on the display screen by hand.
DO NOT use excessive force, or attempt operate them with hard or pointed objects.
The tip of a screw driver, pen or similar object for example may break the screen.
Screen design software for Windows
SW5D5C-GOTR-PACKE Version V5.13P or more (After April 2001)
Screen design software for Windows
SW0PC-FXDU/WIN-E Version V2.50 or more
Graphic operation terminal main unit
Communication cable (GOT ↔ CPU port in FX
or FX
series PLC)
2NC
The connector on the GOT side is straight.
Cable length is 3m (9' 10").
Communication cable (GOT ↔ CPU port in FX
or FX
series PLC)
2NC
The connector on the GOT side is straight. Cable length is 3m (9' 10").
Communication cable (GOT ↔ CPU port in FX
or FX
series PLC)
2NC
The connector on the GOT side is straight.
** M is cable length. 1M: 1m (3' 3"), 10M: 10m (32' 9"), 20M: 20m (65' 7"),
Communication cable (GOT ↔ CPU port in FX, FX
The connector on the GOT side is straight. Cable length is 3m (9' 10").
Communication cable (GOT ↔ CPU port in FX, FX
The connector on the GOT side is straight.
** M is cable length. 10M: 10m (32' 9"), 20M: 20m (65' 7"), 30M: 30m (98' 5")
Communication cable (GOT ↔ CPU port in Q series PLC)
The connector on the GOT side is straight. Cable length is 3m (9' 10").
Data exchange cable (GOT ↔ Personal computer <9-pin D-sub>)
Battery for keeping Alarm history, sampling and current time data
Transparent protection sheet for F940WGOT (5 pieces)
Data transfer adapter (Flash memory built in)
Version
Description
30M: 30m (98' 5")
P L C
P r o g r a m m i n g
p o r t
G O T
, FX
, FX
, FX
0
0S
1S
0N
, FX
, FX
, FX
0
0S
1S
0N
, FX
, FX
, FX
0
0S
1S
0N
, A or QnA series PLC)
2C
, A or QnA series PLC)
2C
, FX
, FX
1N
2N
, FX
, FX
1N
2N
, FX
, FX
1N
2N