  • Page 1 User Guide FTB-5700 Single-Ended Dispersion Analyzer for FTB-400...
  • Page 2 Engineering Inc. (EXFO). Information provided by EXFO is believed to be accurate and reliable. However, no responsibility is assumed by EXFO for its use nor for any infringements of patents or other rights of third parties that may result from its use.
  • Page 3: Table Of Contents

    Contents Contents Certification Information ......................v 1 Introducing the FTB-5700 Single-Ended Dispersion Analyzer ....1 Module Description ........................2 Typical Applications ........................2 Basic FTB-5700 Single-Ended Dispersion Analyzer Operation ..........3 Conventions ..........................5 2 Safety Information ..................7 3 Getting Started with the Single-Ended Dispersion Analyzer ....9 Inserting and Removing Test Modules ..................9...
  • Page 4 Obtaining Online Help ......................76 Contacting the Technical Support Group ................77 Transportation ........................78 9 Warranty ......................79 General Information ......................79 Liability ..........................80 Exclusions ..........................80 Certification ..........................80 Service and Repairs .......................81 EXFO Service Centers Worldwide ..................82 A Technical Specifications ................83 Index .........................85 FTB-5700...
  • Page 5: Certification Information

    F.C.C. Information Electronic test equipment is exempt from Part 15 compliance (FCC) in the United States. However, compliance verification tests are systematically performed on most EXFO equipment. Information Electronic test equipment is subject to the EMC Directive in the European Union.
  • Page 6: Declaration Of Conformity

    Canada G1M 2K2 (418) 683-0211 Equipment Type/Environment: Industrial Scientific Equipment Trade Name/Model No.: FTB-5700 Single-Ended Dispersion Analyzer Standard(s) to which Conformity is Declared: EN 61010-1:2001 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, Part 1: General Requirements.
  • Page 7: Introducing The Ftb-5700 Single-Ended Dispersion Analyzer

    Introducing the FTB-5700 Single-Ended Dispersion Analyzer The FTB-5700 Single-Ended Dispersion Analyzer is the world’s first combined CD and PMD analyzer doing both measurements from a single end of the fiber. It features a single connector port and software for both type of measurements;...
  • Page 8: Module Description

    Handle FTB-5700 Typical Applications With its dynamic range, level of accuracy and feature set, the FTB-5700 Single-Ended Dispersion Analyzer is a perfect tool for any network manager or technician to perform advance testing of 10 Gbit/s networks or faster, on any fiber length up to 120 km. The FTB-5700 Single-Ended Dispersion Analyzer helps validating fiber quality for the given speed or providing information enabling compensation.
  • Page 9: Basic Ftb-5700 Single-Ended Dispersion Analyzer Operation

    Basic FTB-5700 Single-Ended Dispersion Analyzer Operation The purpose of the FTB-5700 Single-Ended Dispersion Analyzer unit is to be simple of use, with minimal parameter setting requirements. The parameter most likely to be changed by a user is the fiber type.
  • Page 10 Introducing the FTB-5700 Single-Ended Dispersion Analyzer Basic FTB-5700 Single-Ended Dispersion Analyzer Operation Once the fiber end event position is found, the unit checks the dynamics and evaluates the wavelength range over which to perform the measurement. It then selects the acquisition conditions and sequence of the measurement before starting the acquisition itself.
  • Page 11: Conventions

    Introducing the FTB-5700 Single-Ended Dispersion Analyzer Conventions Conventions Before using the product described in this manual, you should understand the following conventions: ARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Do not proceed unless you understand and meet the required conditions.
  • Page 13: Safety Information

    Safety Information ARNING Do not install or terminate fibers while a light source is active. Never look directly into a live fiber and ensure that your eyes are protected at all times. ARNING Use of controls, adjustments and procedures for operation and maintenance other than those specified herein may result in hazardous radiation exposure or impair the protection provided by this unit.
  • Page 15: Getting Started With The Single-Ended Dispersion Analyzer

    Getting Started with the Single-Ended Dispersion Analyzer Inserting and Removing Test Modules AUTION Never insert or remove a module while the FTB-400 Universal Test System is turned on. This will result in immediate and irreparable damage to both the module and unit. ARNING When the laser safety LED ( ) is flashing on the FTB-400, at least...
  • Page 16 4. Insert the protruding edges of the module into the grooves of the receptacle’s module slot. 5. Push the module all the way to the back of the slot, until the retaining screw makes contact with the receptacle casing. 6. Place the FTB-400 so that its left panel is facing you. FTB-5700...
  • Page 17 Getting Started with the Single-Ended Dispersion Analyzer Inserting and Removing Test Modules 7. While applying slight pressure to the module, turn the retaining screw clockwise until it is tightened. This will secure the module into its “seated” position. Turn retaining screw knob clockwise FTB-400 left panel (7-slot unit shown)
  • Page 18 Turn retaining screw knob(s) counterclockwise FTB-400 left panel (7-slot unit shown) 4. Place the FTB-400 so that the right panel is facing you. 5. Hold the module by its sides or by the handle (NOT by the connector) and pull it out. FTB-5700...
  • Page 19 Getting Started with the Single-Ended Dispersion Analyzer Inserting and Removing Test Modules AUTION Pulling out a module by a connector could seriously damage both the module and connector. Always pull out a module by its casing. 6. Cover empty slots with the supplied protective covers. AUTION Failure to reinstall protective covers over empty slots will result in ventilation problems.
  • Page 20: Starting The Single-Ended Dispersion Analyzer Application

    Starting the Single-Ended Dispersion Analyzer Application Starting the Single-Ended Dispersion Analyzer Application Your FTB-5700 Single-Ended Dispersion Analyzer module can be configured and controlled from its dedicated ToolBox application. Note: For details about ToolBox, refer to the FTB-400 Universal Test System user guide.
  • Page 21 Getting Started with the Single-Ended Dispersion Analyzer Starting the Single-Ended Dispersion Analyzer Application The main window (shown below) contains all the commands required to control the Single-Ended Dispersion Analyzer: Title Bar The title bar is located at the top of the main window. It displays the module name and its position in the FTB-400 Universal Test System.
  • Page 22: Exiting The Application

    Getting Started with the Single-Ended Dispersion Analyzer Exiting the Application Status Bar The status bar, located at the bottom of the main window, identifies the current operational status of the FTB-5700 Single-Ended Dispersion Analyzer. Module status Battery indicator Current date and time Control mode Local: Module controlled locally only.
  • Page 23: Setting Up The Single-Ended Dispersion Analyzer

    Dispersion Analyzer or a measurement. Once you have acquired this intermediate data, which represents all of the actions done by the unit when performing the test, you can take this file and send it to EXFO for troubleshooting purposes. MPORTANT Selecting the Keep intermediate data option will increase the size of your result file in a significant manner.
  • Page 24 Setting Up the Single-Ended Dispersion Analyzer Setting up Application Details To set up the application details: 1. From the button bar, click Setup. 2. Select the Application tab. FTB-5700...
  • Page 25 Setting Up the Single-Ended Dispersion Analyzer Setting up Application Details 3. Select the units to use for your measurements. 4. If you would like the unit to warn you when a test is complete, select the corresponding option. Single-Ended Dispersion Analyzer...
  • Page 26 Setting Up the Single-Ended Dispersion Analyzer Setting up Application Details 5. If you want your Single-Ended Dispersion Analyzer to keep the intermediate data when performing the analysis, select the corresponding option. FTB-5700...
  • Page 27 Setting Up the Single-Ended Dispersion Analyzer Setting up Application Details 6. Under CD, select the Show lambda-0 check box to show the value if desired (the lambda-0 value is the extrapolated wavelength at which the dispersion equals 0). Single-Ended Dispersion Analyzer...
  • Page 28 Setting Up the Single-Ended Dispersion Analyzer Setting up Application Details 7. Select the display type for the CD values amongst the available choices: Measured wavelength (default value) Step by 1 nm ITU-50 ITU-100 ITU-200 8. To confirm and save the changes, click OK. FTB-5700...
  • Page 29: Customizing Thresholds

    Setting Up the Single-Ended Dispersion Analyzer Customizing Thresholds Customizing Thresholds The Single-Ended Dispersion Analyzer allows you to specify thresholds both for the CD and PMD aspects of your tests to determine if the results are as expected or if they exceed the specified limits. Note: You cannot modify or delete the predefined thresholds provided with your Single-Ended Dispersion Analyzer.
  • Page 30 Custom, the chromatic dispersion and PMD sections become editable and you can specify which values to use for the items below. Dispersion (at 1550 nm) Coefficient (at 1550 nm) Max. dispersion (analysis range) PMD coefficient 4. To confirm and save the changes, click OK. FTB-5700...
  • Page 31: Setting The Wavelength Range

    Setting Up the Single-Ended Dispersion Analyzer Setting the Wavelength Range Setting the Wavelength Range You can set the wavelength range within which you want to perform your acquisitions. You can work with predefined range of the tunable source or set the wavelength range by using the custom option. This option could be useful to perform acquisitions in a specific area of a band or between two bands.
  • Page 32 To use a customized range, disable the Default range option to activate the minimum and maximum value boxes and enter the desired values. 4. Click OK to confirm and save your changes. FTB-5700...
  • Page 33: Setting Pmd And Cd Acquisition Parameters

    Setting Up the Single-Ended Dispersion Analyzer Setting PMD and CD Acquisition Parameters Setting PMD and CD Acquisition Parameters Parameters are kept in memory even after turning off the FTB-400 Universal Test System. These parameters include the following: Parameter Details CD Fiber Type There are several types of CD fibers.
  • Page 34 If the fiber installations are, for example, between aerial sections buildings, or suspended to reach the intended location, the movement created by wind or other outside elements can affect the PMD measurement. Select this option to compensate for such possible movements. FTB-5700...
  • Page 35 Setting Up the Single-Ended Dispersion Analyzer Setting PMD and CD Acquisition Parameters To set the acquisition parameters: 1. From the button bar, click Setup. Single-Ended Dispersion Analyzer...
  • Page 36 Setting Up the Single-Ended Dispersion Analyzer Setting PMD and CD Acquisition Parameters 2. Select the Acquisition tab. 3. Change the settings as needed according to the table above. 4. Click OK to confirm and save your changes. FTB-5700...
  • Page 37: Defining The Automatic Fiber Name Format

    Setting Up the Single-Ended Dispersion Analyzer Defining the Automatic Fiber Name Format Defining the Automatic Fiber Name Format Each time you make a new acquisition, the fiber name changes automatically according to a pattern you will have previously defined. This name corresponds to the concatenation of a static part (prefix) and a variable part that will be incremented.
  • Page 38: Managing Test Configurations

    To save a configuration: 1. Set the parameters on your unit as desired. 2. From the main window, click Setup. 3. Select the Configuration tab. FTB-5700...
  • Page 39 Setting Up the Single-Ended Dispersion Analyzer Managing Test Configurations 4. Click Export Configuration. 5. Select the location and name for your file, then click Save. Single-Ended Dispersion Analyzer...
  • Page 40 Setting Up the Single-Ended Dispersion Analyzer Managing Test Configurations To retrieve an existing configuration file: 1. From the main window, click Setup. 2. Select the Configuration tab. FTB-5700...
  • Page 41 Setting Up the Single-Ended Dispersion Analyzer Managing Test Configurations 3. Click Import Configuration. 4. Locate the file corresponding to your configuration, then click Open. Single-Ended Dispersion Analyzer...
  • Page 42 Setting Up the Single-Ended Dispersion Analyzer Managing Test Configurations To revert to the default configuration: 1. From the main window, click Setup. 2. Select the Configuration tab. FTB-5700...
  • Page 43 Setting Up the Single-Ended Dispersion Analyzer Managing Test Configurations 3. Click Default Configuration. Single-Ended Dispersion Analyzer...
  • Page 44: Setting Test Preferences

    You can set the autonaming and information preferences for your tests. This will help you better identify the different tests you perform with your module. To set the test preferences: 1. From the main window, click Setup. 2. Select the Preferences tab. FTB-5700...
  • Page 45 Setting Up the Single-Ended Dispersion Analyzer Setting Test Preferences 3. Enter the information pertaining to your test. This information will be attached to the acquisitions you perform afterwards. 4. If you want the application to automatically include the fiber prefix, cable name, A and B location or date in the file name scheme, select the corresponding option.
  • Page 47: Operating The Single-Ended Dispersion Analyzer

    To ensure maximum power and to avoid erroneous readings: Always clean fiber ends as explained below before inserting them into the port. EXFO is not responsible for damage or errors caused by bad fiber cleaning or handling. Ensure that your patchcord has appropriate connectors. Joining mismatched connectors will damage the ferrules.
  • Page 48: Installing The Exfo Universal Interface (Eui)

    Operating the Single-Ended Dispersion Analyzer Installing the EXFO Universal Interface (EUI) Installing the EXFO Universal Interface (EUI) The EUI fixed baseplate is available for connectors with angled (APC) or non-angled (UPC) polishing. A green border around the baseplate indicates that it is for APC-type connectors.
  • Page 49: Performing A Test

    You can test the PMD, the CD, or both at the same time. MPORTANT Your FTB-5700 Single-Ended Dispersion Analyzer was designed to automatically determine the length of your fiber and test accordingly. If the test is still performed and the length indicated is not appropriate, this mean that a strong reflective event is present on the fiber before the non-reflective termination.
  • Page 50 2. Select whether the acquisition will include PMD, CD, or both. 3. Verify that the fiber (FUT) is properly connected and that the setup is appropriate. MPORTANT The FUT must be terminated by a UPC connector. FTB-5700...
  • Page 51 Operating the Single-Ended Dispersion Analyzer Performing a Test 4. From the button bar, click Start to start a measurement sequence. When the measurement is complete, the results are displayed in the grid. 5. If you are satisfied with the results, click Save. The entry will be sent to the Results tab.
  • Page 53: Managing Results

    Managing Results Your FTB-5700 Single-Ended Dispersion Analyzer allows you to work with two types of results: Newly acquired results Results loaded from existing files To view and analyze your results, the application provides: A graph and a table presenting details for a specific acquisition in the...
  • Page 54 From the main window Results tab, once you have taken a measurement and saved it, or opened measurement files, you can select the fiber for which you want to view the results. To view CD Details: In the Fiber Test tab, click Details. In the Results tab, click CD Details. FTB-5700...
  • Page 55 Managing Results To specify the type of display to show on the graph: In the CD Display window, under the graph, select either Chromatic dispersion or Chromatic dispersion coefficient. The graph and the results in the Display table will change accordingly. Single-Ended Dispersion Analyzer...
  • Page 56: Modifying Analysis Parameters And Related Information

    To modify cable information for your test: 1. Acquire test results by performing a scan, or retrieve a file or files from the Open button. 2. In the Results tab, press Edit. FTB-5700...
  • Page 57 Managing Results Modifying Analysis Parameters and Related Information 3. Select the Cable tab. 4. Fill the boxes according to your needs. 5. When you are done, click Save. Single-Ended Dispersion Analyzer...
  • Page 58 To modify job information for your test: 1. Acquire test results by performing a scan, or retrieve a file or files from the Open button. 2. In the Results tab, press Edit. FTB-5700...
  • Page 59 Managing Results Modifying Analysis Parameters and Related Information 3. Select the Job tab. 4. Fill the boxes according to your needs. 5. When you are done, click Save. Single-Ended Dispersion Analyzer...
  • Page 60 To modify threshold parameters for your test: 1. Acquire test results by performing a scan, or retrieve a file or files from the Open button. 2. In the Results tab, press Edit. 3. Select the Threshold tab. FTB-5700...
  • Page 61 Managing Results Modifying Analysis Parameters and Related Information 4. Change the desired threshold settings (for details on the settings, see Customizing Thresholds on page 23). 5. Save your analysis parameters; the results are changed accordingly by your unit. Single-Ended Dispersion Analyzer...
  • Page 62 The analysis parameters include the analysis range and the fiber type. To modify analysis parameters for your test: 1. Acquire test results by performing a scan, or retrieve a file or files from the Open button. 2. In the Results tab, press Edit. 3. Select the Analysis tab. FTB-5700...
  • Page 63 Managing Results Modifying Analysis Parameters and Related Information 4. Change the desired analysis settings (for details on the settings, see Setting PMD and CD Acquisition Parameters on page 27). 5. Save your analysis parameters; the results are changed accordingly by your unit.
  • Page 64: Opening Existing Files

    To open an existing file: 1. From the button bar, click Open. A standard Open dialog box is displayed, allowing you to choose the desired file. 2. When you are done, from the displayed dialog box, click Open to load the files. FTB-5700...
  • Page 65: Removing Unwanted Results

    Managing Results Removing Unwanted Results Removing Unwanted Results When a problem occurs, such as a fiber break, you may want to remove the corresponding erroneous measurement. This could be useful to avoid distorting results and statistics. MPORTANT Removing a saved file using the Delete button will remove the file from the drive.
  • Page 66: Closing Result Files

    Note: You do not need to close files manually before exiting the Single-Ended Dispersion Analyzer application. You will be prompted if some result files have not been saved. To close files: 1. In the Results tab, select the file to close. 2. Click Close. FTB-5700...
  • Page 67: Generating A Report

    Managing Results Generating a Report Generating a Report You can generate an html report for the currently selected file. To generate a report: 1. From either the Fiber Test or Results window, click Report. 2. Select a name and location for your report. 3.
  • Page 69: Maintenance

    Maintenance To help ensure long, trouble-free operation: Always clean fiber-optic connectors before using them. Keep the unit free of dust. Clean the unit casing and front panel with a cloth slightly dampened with water. Store unit at room temperature in a clean and dry area. Keep the unit out of direct sunlight.
  • Page 70: Cleaning Eui Connectors

    3. Slowly insert the cleaning tip into the EUI adapter until it comes out on the other side (a slow clockwise rotating movement may help). 4. Gently turn the cleaning tip one full turn, then continue to turn as you withdraw it. FTB-5700...
  • Page 71 6c. With a dry lint-free wiping cloth, gently wipe the same surfaces to ensure that the connector and ferrule are perfectly dry. 6d. Verify connector surface with a portable fiber-optic microscope (for example, EXFO’s FOMS) or fiberinspection probe (for example, EXFO’s FIP). ARNING Verifying the surface of the connector WHILE THE UNIT IS ACTIVE WILL result in permanent eye damage.
  • Page 72: Recalibrating The Unit

    You should determine the adequate calibration interval for your unit according to your accuracy requirements. Under normal use, EXFO recommends calibrating your unit every year. FTB-5700...
  • Page 73: Recycling And Disposal (Applies To European Union Only)

    This equipment was sold after August 13, 2005 (as identified by the black rectangle). Unless otherwise noted in a separate agreement between EXFO and a customer, distributor or commercial partner, EXFO will cover costs related to the collection, treatment, recovery, and disposal of...
  • Page 75: Troubleshooting

    Note: Should you have problems, you can activate the Keep intermediate data option in the Acquisition tab of the Setup window and send the resulting file to EXFO. This will allow us to help troubleshooting the problem. General Problems Message...
  • Page 76 Add a reflective termination at the end The wavelength range is of the fiber. too large. Reduce the wavelength range in the Acquisition tab of the Setup window, or select Default as the wavelength range value. FTB-5700...
  • Page 77 Troubleshooting Solving Common Problems PMD-Related Problems Message Possible cause Solution Conditions are not optimal Too much loss in the fiber Clean the fiber end. for measuring polarization under test. Add a reflective mode dispersion. Cannot termination at the end perform measurement. of the fiber.
  • Page 78 Impossible to find a valid Too much loss in the Clean the fiber end. measurement range. fiber under test. Add a reflective termination at the end Unsuitable FUT. The of the fiber. FUT must not cut the 1550 nm wavelength. FTB-5700...
  • Page 79 If some movement is inevitable (fiber is outside with aerial sections), make sure that the Fiber with aerial sections option is selected in the Setup tab of the Acquisition window. Contact EXFO if the problem is still not solved. Single-Ended Dispersion Analyzer...
  • Page 80 The wavelength Select a wavelength range that selected range. range is unsuitable suits the FUT and the instrument for this FUT. range. You can set the wavelength range in the Acquisition tab of the Setup window. FTB-5700...
  • Page 81 Troubleshooting Solving Common Problems Message Possible cause Solution There are not enough Fiber end is too If you have put a reflective valid points to compute reflective. termination at the end of the the model fit due to fiber, remove it. Unsuitable FUT.
  • Page 82: Obtaining Online Help

    Troubleshooting Obtaining Online Help Obtaining Online Help An online version of the FTB-5700 Single-Ended Dispersion Analyzer user guide is conveniently available at all times from the application. Note: You will also find a printable PDF version on your installation CD.
  • Page 83: Contacting The Technical Support Group

    Contacting the Technical Support Group To obtain after-sales service or technical support for this product, contact EXFO at one of the following numbers. The Technical Support Group is available to take your calls from Monday to Friday, 8:00 a.m. to 7:00 p.m.
  • Page 84: Transportation

    Pack the unit in its original packing material when shipping. Avoid high humidity or large temperature fluctuations. Keep the unit out of direct sunlight. Avoid unnecessary shocks and vibrations. FTB-5700...
  • Page 85: Warranty

    EXFO Electro-Optical Engineering Inc. (EXFO) warrants this equipment against defects in material and workmanship for a period of one year from the date of original shipment. EXFO also warrants that this equipment will meet applicable specifications under normal use. During the warranty period, EXFO will, at its discretion, repair, replace,...
  • Page 86: Liability

    Liability Liability EXFO shall not be liable for damages resulting from the use of the product, nor shall be responsible for any failure in the performance of other items to which the product is connected or the operation of any system of which the product may be a part.
  • Page 87: Service And Repairs

    5. Return the equipment, prepaid, to the address given to you by support personnel. Be sure to write the RMA number on the shipping slip. EXFO will refuse and return any package that does not bear an RMA number.
  • Page 88: Exfo Service Centers Worldwide

    Warranty EXFO Service Centers Worldwide EXFO Service Centers Worldwide If your product requires servicing, contact your nearest authorized service center. EXFO Headquarters Service Center 400 Godin Avenue 1 866 683-0155 (USA and Canada) Quebec (Quebec) G1M 2K2 Tel.: 1 418 683-5498...
  • Page 89: A Technical Specifications

    The following technical specifications can change without notice. The information presented in this section is provided as a reference only. To obtain this product’s most recent technical specifications, visit the EXFO Web site at www.exfo.com. SPECIFICATIONS Measured wavelength range (nm)
  • Page 91: Index

    ........77 chromatic dispersion......49 analysis parameters ........56 threshold ..........23 application configurations ..........32 contacting EXFO support from ....78 connectors, cleaning........64 exiting ........... 16 contact information, EXFO ......78 starting, single-module......14 conventions, safety........5 application details ........
  • Page 92 ..........23 polarization maintaining fiber ..... 28 position, module ......... 15 label, identification ........77 preferences, test .......... 38 product identification label ......... 77 maintenance specifications ......... 83 EUI connectors........64 front panel ..........63 general information....... 63 FTB-5700...
  • Page 93 81 certification..........80 service centers ..........82 exclusions ..........80 setting wavelength range......25 general........... 79 shipping to EXFO ........81 liability ........... 80 slot number..........15 null and void.......... 79 software. see application wavelength range........25 specifications, product ........
  • Page 94 EXFO ASIA-PACIFIC 151 Chin Swee Road SINGAPORE 169876 #03-29, Manhattan House Tel.: +65 6333 8241 · Fax: +65 6333 8242 TOLL-FREE (USA and Canada) 1 800 663-3936 © 2008 EXFO Electro-Optical Engineering Inc. All rights reserved. Printed in Canada (2008-07)

Table of Contents