Lincoln Electric Power Feed 25M Operator's Manual page 62

Hide thumbs Also See for Power Feed 25M:
Table of Contents

Advertisement

POWER FEED™ 25M
INSTALLATION OF THE K590-6 WATER COOLING KIT
ELECTRIC SHOCK can kill.
WARNING
• Turn the input power OFF at the disconnect
switch before working on this equipment.
• Do not touch electrically hot parts.
• Only qualified personnel should install, use
or service this equipment.
-------------------------------------------------
-----------------------
The K590-6 components are rated up to 70 psi (5 bar) and
158°F (70°C). Use a coolant fluid that is compatible with the
water cooler and the gun.
Tools required:
• 3/8" wrench
• 5/16" nut driver
• medium flat bladed screw driver
• cutting tool
1. Turn power off at the welding power source.
2. Remove the screws securing the case to the inner module
using a 3/8" wrench. (and a 5/8" wrench for plastic case
models).
3. Remove the bolts holding the handle to the case with a 5/8"
wrench
REMOVE 2 BOLTS AND WASHERS FROM HANDLE
4. Remove the module from the case by lifting the front of the
module approximately .25" (6 mm) and then sliding forward.
5. Use a 5/16" nut driver to remove the screws holding the water
cooling cover on the case front of the inner module and on the
rear of the case.
6. Install the fitting and hose assembly to the case front. Route
the hoses along the bottom of the inner module and out
through the cutout of the cover. Slide the module back into
the case.
7. Assemble the handle to the inner module and case.
ASSEMBLE BOLTS AND WASHER TO HANDLE