The physical disk are of different types
The physical disk used as a dedicated hot spare must be the same type as the physical disks that are already part of the virtual disk. For
example, if a virtual disk consists of SATA-II physical disks, the dedicated hot spare must be a SATA-II physical disk.

Cannot create a global hot spare

If you cannot create a global hot spare, check the following causes:
1
There are no empty physical disks available or the physical disks have not been converted to RAID-capable
2
The physical disk is already part of a virtual
3
The physical disk assigned as the global hot spare has
4
The physical disk assigned as the global hot spare is
There are no empty physical disks available or the physical disks have not
been converted to RAID-capable disks
Install additional physical disks and convert them to a RAID-capable disk, If existing physical disks are Non-RAID they need to be converted
to RAID-capable disks.
WARNING:
When a physical disk is converted to RAID Capable disks, all data on the physical disk is lost.
NOTE:
A physical disk with a Non-RAID status can be converted to a RAID-Capable disk, if desired, but it is no longer Non-RAID
(Converting to RAID-Capable adds PERC S140 configuration information to the physical disk).
The physical disk is already part of a virtual disk
A hot spare cannot be selected if it is already part of an existing virtual disk.
The physical disk assigned as the global hot spare has failed
When prompted at system startup, press Ctrl+R to access the BIOS Configuration Utility Ctrl+R. In the BIOS Configuration Utility Ctrl
+R, select View Virtual Disk Details and press Enter. Determine whether the physical disk that is designated as the global hot spare has a
status of Failed.
1
Check to see if the physical disk is malfunctioning or is physically disconnected.
2
Select another physical disk as the global hot spare.
The physical disk assigned as the global hot spare is missing
Check to see if the physical disk was removed from the backplane or cable connection, or whether the cables from the controller to the
physical disk are disconnected or faulty.
Perform a rescan to verify that the physical disk is still missing.