Any action against National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service failures caused by owner’s failure to follow the National...
Page 4
Any use or application of National Instruments products for or involving medical or clinical treatment must be performed by properly trained and qualified...
Page 5
The BNC-208X Series User Manual is organized as follows: • Chapter 1, Introduction, describes the BNC-208X Series boards; lists the contents of your BNC-2080 and BNC-2081 kits; describes the optional equipment, signal conditioning accessories, and software support; and explains how to unpack your BNC-208X Series board.
Page 7
SC-206X Series User Manual (part number 320200-01) • SC-207X Series User Manual (part number 320239-01) The following National Instruments documents may also be helpful to you depending on the type of system you are using with your BNC-208X Series boards: •...
Page 9
Hardware Installation for the BNC-2080 and the BNC-2081......4-1 Installing the SC-205X Series Cable Adapter Boards ........4-2 Installing the SC-207X General-Purpose Termination Breadboards....4-2 Rack Mounting....................4-2 External Power Connection (If Necessary)............4-5 BNC-208X Series Board Connection ..............4-6 Signal Connections ......................4-7 Ribbon-Cable Connectors..................4-7 Rack-Mount Chassis Cover Attachment............4-7 Appendix Customer Communication ....................A-1...
Page 10
DAC0 OUT Schematic..................3-14 Figure 3-13. Analog Output Schematic for DACs, DAC0 OUT Shown ......3-14 Figure 4-1. Mounting Locations for the BNC-208X Series Board and SC-207X Series Board......................4-3 Figure 4-2. Mounting Locations for the BNC-208X Series Board and SC-205X Series Board or SC-206X Series Board............4-3 Figure 4-3.
Page 11
Contents Tables Table 1-1. Data Acquisition Boards for Use with BNC-208X Series Boards ....1-1 Table 2-1 Switch S5 Settings for National Instruments Data Acquisition Boards ...2-3 Table 2-2. DIFF Mode Channel Component Positions............2-5 Table 2-3. Data Acquisition Boards Used with the BNC-2080 Board ......2-7 Table 3-1.
Table 1-1 lists the specific data acquisition boards that can currently be used with the BNC-208X Series boards. Table 1-1. Data Acquisition Boards for Use with BNC-208X Series Boards...
206X Series signal conditioning board, and an SC-207X Series general-purpose termination breadboard in a 19-in. rack-mount chassis. You can mount your BNC-208X Series board on the left or right side of the rack mount. Mounting the BNC-208X Series board on the left side and running the cable under the BNC-208X Series board to connect to the any of the SC Series boards will make access to both boards easier.
BNC-2081 board 181635-01 You can identify which version of the BNC-208X Series kit you have by looking up the part number in the preceding table. In addition to the board, each version of the BNC-208X Series kit contains the following component.
Unpacking Your BNC-208X Series board is shipped in an antistatic package to prevent electrostatic damage to the board. Several components on the board can be damaged by electrostatic discharge. To avoid such damage in handling the board, take the following precautions: •...
The BNC-2080 board is used with the National Instruments data acquisition boards for the Macintosh NuBus (NB Series), IBM PS/2 Micro Channel (MC Series), and PC/XT/AT and compatible computers.
I/O pins in position B, and to pins 49 (+5 V) and 50 (DGND) in position C. Table 2-1 shows the setting to be used with each of the National Instruments data acquisition boards. Table 2-1. Switch S5 Settings for National Instruments Data Acquisition Boards...
For more information on the SC-205X Series boards, the SC-206X Series boards, or the SC- 207X Series boards, refer to either your National Instruments catalog, the SC-205X Series User Manual, the SC-206X Series User Manual, or the SC-207X Series User Manual.
Figure 2-5. Direct Connection between an MIO-16 Board and the BNC-2080 Board If any signal conditioning of the digital I/O ports with the National Instruments SC-206X Series boards is desired, then the SC-2050 cable adapter board must be used with the data acquisition boards listed in Table 2-2.
Page 31
E and F. The closest standard 5% tolerance resistors are 20 kΩ. The closest standard 0.5% resistors are 19.8 kΩ. National Instruments recommends using 1% or better tolerance resistors in this application because differences between the resistor values degrade the common-mode rejection ratio (CMRR).
Input voltages greater than 42 V can result in damage to the BNC-2080 board, any and all boards connected to it, and the host computer. Overvoltage can also cause an electric shock hazard for the operator. National Instruments is not liable for damage or injury resulting from such misuse.
When the MIO-16 is configured for ±10-V inputs, the board can acquire ±30-V signals with this attenuator circuit. If the use of thermocouples is required in your applications, using National Instruments SC-2070 board is better suited for the task. The SC-2070 board is equipped with an onboard temperature sensor for use with thermocouple cold-junction compensation.
I/O ports. This connector is in the standard pinout for connection to one of National Instruments DIO-24 boards. The BNC-2081 board is used with the National Instruments Lab data acquisition boards for the Macintosh (Lab-NB and Lab-LC), IBM PC/XT/AT, and compatible computers (Lab-PC and Lab-PC+).
Lab board user manual for information on the use of these signals. If you want screw terminal access to all signals, a National Instruments SC-2071 board can be used in conjunction with the BNC-2081 board. If you want optical isolation of or relay control by the digital I/O lines, you must use a National Instruments SC-2053 cable adapter board and the appropriate SC-206X Series digital signal conditioning board.
SC-206X Series Board, via the SC-2053 Board Warning: Do not connect the BNC-2081 board to any board other than a National Instruments Lab data acquisition board, the SC-2053 cable adapter board, or the SC-2071 board. The BNC- 2081 board is not compatible with any other data acquisition boards or cable adapter boards.
Input voltages greater than 42 V can result in damage to the BNC-2081 board, any and all boards connected to it, and the host computer. Overvoltage can also cause an electric shock hazard for the operator. National Instruments is not liable for damage or injury resulting from such misuse.
This chapter explains how to install and make connections to the BNC-208X Series boards. Hardware Installation Most of the sections that follow apply to all the BNC-208X Series boards. However, several topics are more board-specific than others. Unless a given topic is delineated by board, the topic applies to all BNC-208X Series boards.
BNC-208X Series board on the left or right side of the 19-in. rack mount. Mounting the BNC-208X Series board on the left side of the rack and any other of the SC Series boards on the right side of the rack will make access to both boards easier.
Installation and Connections Chapter 4 Mount the BNC-208X Series board in the chassis by removing the screws on the bottoms of the four standoffs attached to the board and using the same screws to attach the board to the mounting rack. The two standoffs in the center of the board are for support only and have no screws to attach the board to the rack as shown in Figure 4-3.
SC-206X Series digital signal conditioning boards, such as the SC-2062 board, are being used on the same data acquisition board as the BNC-208X Series board, some of these boards need to be powered by an external +5-VDC supply. Because the SC-206X Series boards draw much more current...
Chapter 4 Installation and Connections A 50-pin ribbon cable connects your BNC-208X Series board to either an SC-205X Series board, an SC-207X Series board, or directly to the data acquisition board. Remember to turn the host computer off before making any connections. One end of the ribbon cable connects to the BNC-208X Series board at connector J1 or J2.
Filling out a copy of the Technical Support Form before contacting National Instruments helps us help you better and faster. National Instruments provides comprehensive technical assistance around the world. In the U.S. and Canada, applications engineers are available Monday through Friday from 8:00 a.m. to 6:00 p.m.
Page 62
National Instruments for technical support helps our applications engineers answer your questions more efficiently. If you are using any National Instruments hardware or software products related to this problem, include the configuration forms from their user manuals. Include additional pages if necessary.
Page 63
Documentation Comment Form ___________________________________________________ National Instruments encourages you to comment on the documentation supplied with our products. This information helps us provide quality products to meet your needs. Title: BNC-208X Series User Manual Edition Date: September 1993 Part Number: 320407-01 Please comment on the completeness, clarity, and organization of the manual.