Burner Commissioning - Realfires 650 Installation Instructions Manual

Table of Contents

Advertisement

Installation instructions - Burner into rebox
The burner is supplied boxed complete with, fi rebox refl ectors, grate, ash cover, vermiculite, logs, & coals.
To make the gas connection, place the burner in the fi rebox so that the back of the burner is touching the back of
the fi rebox and is positioned central. The gas pipe should be bent into position and marked for cutting.
Remove the burner cut the pipe and make a fl are connection. Re fi t the burner into the fi rebox ensuring it is
touching the back of the fi rebox. Connect the gas pipe. Test for soundness. Remove plastic protective fi lm from
side refl ectors. Position refl ectors each side of fi rebox and fi t the front grate onto the brackets at the front of the
burner. The Grate holds the refl ectors in place.
Natural Gas burner
Fill the burner tray with the vermiculite supplied ensuring the burner tube is completely covered. Lay logs and
coals on top of the vermiculite as shown in the log/coal layout drawing. Note that the shelf at the back of the
burner is also used. Do not place logs or coals close to the pilot. It is important that the coals are not too tight-
ly placed as this will a ect heat output. The fl ame picture and radiant glow is better when there is good spacing
between the coals.
L.P.G. Burner
The L.P.G. burner is a fl at steel burner. This burner is supplied with a bag of coarse vermiculite, spread this thinly
(5 to 10mm) over the surface of the burner. Follow instructions for coal placement as with Natural Gas burner.
Optional Electric On/Off option
If the burner is fi tted with an electric On/O solenoid, there will be an electrical lead with a connector plug in the
base of the fi re. The plug connects to the solenoid. The electrical lead should be wired to a wall switch by an
electrician. The burner will not operate without electrical supply to the solenoid.

Burner Commissioning

Turn the control knob to ignite the pilot, this may take several attempts until air has been purged. Once the pilot is
alight, keep the control knob depressed for about 20 seconds. Then release and turn on the main burner.
Check that the fl ame travels easily across the burner and that coal placement does not a ect ignition.
Re-position coals if required.