Page 2
MODEL XT30/XT50 XT SERIES™ INSTALLATION GUIDE FCC NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Earth Ground ...................... 7 Replacement Period .................... 7 6.4 Discharge/Recharge .................... 7 6.5 Battery Supervision ..................... 7 XT30/XT50 Power Requirements ................7 XT30/XT50 Standby Battery Calculations .............. 8 Bell Output Terminals 5 and 6 ....................9 Keypad Data Bus 8.1 Description ......................9 8.2 Terminal 7 - RED....................
Page 4
Wireless Audible Annunciation ................16 21.7 Panel location ....................16 21.8 Test Frequency ....................16 Digital Burglar Alarm Communicator System Units ANSI/UL 1635 22.1 Entry Delay .......................16 22.2 Exit Delay ......................16 22.3 Test Frequency ....................16 22.4 Automatic Bell Test ....................16 Digital Monitoring Products XT30/XT50 Installation Guide...
Page 5
26.2 Call Waiting .......................19 26.3 Entry Delay .......................19 26.4 Local Bell ......................19 26.5 Minimum Installation Requirements ..............19 Troubleshooting 27.1 Troubleshooting Section ..................20 27.2 Common LCD Keypad Displays ................20 Wiring Diagrams 28.1 Multiple Indicating Circuit Modules Installation .............21 28.2 System Sensor 2-Wire Smoke Detectors ..............22 Revisions to This Document Digital Monitoring Products XT30/XT50 Installation Guide...
• XT50 has 20 additional onboard wireless zones numbered 80-99 Outputs The XT30/XT50 panels provide four open collector outputs rated for 50mA each. A Model 300 Output Harness is required. The open collector outputs provide the ground connection for a positive voltage source.
Metal Oxide Varistors and Transient Voltage Suppressors help protect against voltage surges on input and output circuits. This transient protection provides additional resistance to electrical surges such as lighting. Additional surge protection is available by installing the DMP 370 or 370RJ Lightning Suppressors. Digital Monitoring Products XT30/XT50 Installation Guide...
263H HSPA + Cellular Allows you to connect the XT30/XT50 Series to any compatible HSPA+/SMS network. Communicator Card The 263H is compatible with XT30 and XT50 Series control panels, version 112 or higher. Zone and Output Expansion Modules 710 Bus Splitter/Repeater Increases keypad wiring distance to 2500 feet.
POWER LIMITED operation, testing, maintenance, evacuation planning, and repair Suitable for DACT Central Station. All circuits on the Model XT30/XT50 comply service is to be provided with this equipment. Warning: Owner’s with the requirements for inherent power Suitable for Household Fire and instruction notice, not to be removed by anyone except occupant.
The transformer must be connected to a 120VAC 60 Hz commercial power outlet that is not con trolled by a wall switch. Never share the transformer output with any other equipment. Power LED When either AC transformer power or DC battery power is connected to the panel the PWR LED shows steady green. Digital Monitoring Products XT30/XT50 Installation Guide...
Use 12VDC sealed lead-acid rechargeable battery. Batteries supplied by DMP have been tested to ensure proper charging with DMP products. GEL CELL BATTERIES CANNOT BE USED WITH THE XT30/XT50 PANEL. Earth Ground Terminal 4 of the panel must be connected to earth ground using 14 gauge or larger wire to provide proper transient suppression.
Terminals 7, 8, 9, and 10 of the panel are designated as the keypad data bus. In addition to keypads, the XT30/XT50 allows the connection of any combination of zone expansion modules, Glassbreak Detectors, and PIRs to the keypad bus up to the maximum of eight devices.
11. Burglary Zones 10.1 Description On XT30/XT50 panels, terminals 12 to 24 are the nine burglary zones. For programming purposes, the zone numbers are 1 to 9. The zone configurations on terminals 12 to 24 are described below. Terminal...
A resettable 2-wire Class B powered zone is provided on terminals 25 (positive) and 26 (negative) of the panel. For programming purposes, the zone number is 10 on the XT30/XT50. The zone uses a Model 309, 3.3k Ohm EOL resistor (provided with the panel) and has an operating range of 8.8 to 13.9VDC.
The two LEDs, located on the left side of the ETHERNET Connector, indicate network operation. The top, Link LED is a steady green light when an ethernet cable is connected. The bottom, Activity LED flashes yellow to indicate messages are being received or transmitted. Digital Monitoring Products XT30/XT50 Installation Guide...
The RESET header is located just above the terminal strip on the right side of the circuit board and is used to reset the XT30/XT50 microprocessor. To reset the panel when first installing the system, install the reset jumper before applying power to the panel. After connecting the AC and battery, remove the reset jumper.
Outputs Load using the included cable and operates at 12VDC from the panel power supply. The 763 Wi-Fi Module is compatible with all DMP XT30/ XT50 Series control panels with Level L hardware and Version 124 or higher firmware. Reset...
Power/Armed LED turns Blue on Graphics keypads or Green on LCD keypads. To enable association operation in the XT30/XT50 panel, reset panel three Figure 12: Transmit and times allowing the keypad bus transmit light to begin flashing between Receive LED’s...
Use battery Models 365 (12VDC 9Ah) or 366 (12VDC 18Ah) with the XT30/XT50 panel when installed in the 340, 341, 349, or 349A enclosures. The Model 364 (12VDC 1.3Ah) battery is for use with the XT30/XT50 panel when using the 341 enclosure with the optional 341B Battery Bracket. The Model 364 battery is rated for 4 hours of standby time.
Monthly Limit or additional cellular charges may apply. Digital Dialer Central Station (DACT) service for commercial application can be provided by adding a listed local audible signal appliance and placing the XT30 or XT50 panel into the Model 349A Attack Resistant Enclosure.
17.5 Walk Test Not Allowed * Programming at installation may be subordinate to other listed requirements for the intended application. ** For listed Installations, combined Entry Delay and Transmit Delay should not exceed 1 minute. Digital Monitoring Products XT30/XT50 Installation Guide...
26.3 Entry Delay Only use Entry Delay 1. Do not use Entry Delay 2. See the XT30/XT50 Programming Guide. 26.4 Local Bell All non-fire zones such as Night, Day, Exit, Aux1 and Aux 2 must be programmed for local bell enabled with a bell cutoff time set to a minimum of 6 minutes to provide a cancel window of 5 minutes or greater.
TROUBLESHOOTING Troubleshooting 27.1 Troubleshooting Section This section provides troubleshooting information for use when installing or servicing an XT30/XT50 system. Problem Possible Cause Possible Solutions RESET Jumper is installed. Remove the RESET reset jumper. Open or short on the green data wire to Check for broken or shorted wires between Keypad displays “SYSTEM TROUBLE” the keypad. the panel and the keypad. Bad keypad or zone expander is affecting Replace keypad or zone expander. the Green data wire.
SYSTEM SENSOR LOOP OUT + TEST & MAINTENANCE MODULE OUT - IN + IN - 3.3K Z10+ 470 Ohm or Z10- (2) 1k in Parallel Orange Yellow 3.9K EOL SYSTEM SENSOR 2WTA-B or 2WTR-B SMOKE DETECTORS Digital Monitoring Products XT30/XT50 Installation Guide...
Page 29
Digital Monitoring Products XT30/XT50 Installation Guide...
Page 30
Certifications ANSI/SIA CP-01 False Alarm Reduction ANSI/UL 1023 Household Burglar ANSI/UL 985 Household Fire Warning ANSI/UL 1610 Central Station Burglar ANSI/UL 1635 Digital Burglar California State Fire Marshal (CSFM) FCC Part 15 Registration ID CCKPC0096 FCC Part 68 Registration ID CCKAL00BXT50 8 0 0 - 6 4 1 - 4 2 8 2 I N T R U S I O N •...